Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

7126–7150 of 40520

  • HighFDA (Devices)·Z-2364-2024·2024-07-24

    Abbott Proclaim Plus 5 Pulse Generator Battery Life Shorter Than Labeled

    Abbott is recalling 8,401 units of the Proclaim Plus 5 Implantable Pulse Generator because the battery may reach end-of-service sooner than the product labeling indicates.

    Product
    Abbott Proclaim Plus 5 Implantable Pulse Generator, REF 3670, Sterile EO, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2375-2024·2024-07-24

    Blood collection tubes recalled for missing additive and separation failures

    Greiner Bio-One is recalling VACUETTE blood collection tubes due to missing additive affecting clotting and separation. Defective tubes could delay patient treatment if samples require recollection.

    Product
    VACUETTE¿ TUBE 8 ml CAT Serum Separator Clot Activator 16x100 red cap-yellow ring, non-ridged
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2371-2024·2024-07-24

    Hip Prosthesis Component Mislabeled; Package Size May Not Match Device

    Howmedica Osteonics is recalling 18 units of UNITRAX Endoprosthesis Head Components due to mislabeled package sizes. The label may not match the actual device size inside.

    Product
    UNITRAX Endoprosthesis Head Component - 42mm. Implantable component used in partial hip arthroplasty. Catalog Number: 6942-5-042
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2399-2024·2024-07-24

    IV Infusion Pump Sets Recalled for Backcheck Valve Malfunction

    B. Braun is recalling Infusomat IV infusion pump sets due to potential backcheck valve malfunction that can cause medication to flow backward between IV containers and prevent proper medication delivery.

    Product
    Infusomat UNIV. 15 DROP PUMP SET W/2 CARESITE CV- Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/ Catalog Number 490102
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2386-2024·2024-07-24

    Infusion Pump Set Recalled for Potential Backcheck Valve Malfunction and Medication Backflow

    B. Braun's Infusomat UNIV. 15 IV infusion pump set is being recalled due to a potential backcheck valve malfunction that could cause medication to backflow from secondary into primary IV containers, potentially resulting in patient injury.

    Product
    Infusomat UNIV. 15 DROP PUMP SET W/3 SAFELINE, ASV-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 363030
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2401-2024·2024-07-24

    Infusomat UNIV 60 IV Infusion Pump Set Recalled for Valve Malfunction Risk

    B. Braun is recalling Infusomat UNIV 60 IV infusion pump sets due to a backcheck valve defect that could cause medication backflow between IV containers and prevent priming, potentially resulting in adverse drug reactions or medication loss.

    Product
    Infusomat UNIV 60 DROP PUMP SET, W/2 CARESITE INJ. -Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/ Catalog Number : 490104
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2397-2024·2024-07-24

    IV Infusion Pump Set Valve May Cause Dangerous Medication Backflow

    B. Braun's Infusomat pump sets may have faulty backcheck valves causing medication to backflow between IV bags, risking reduced medication delivery and adverse reactions. All units distributed worldwide after August 2023 are affected.

    Product
    Infusomat UNIV. 15 DROP PUMP SET W 3 CARESITE L.L. Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/ Catalog Number: 490100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2393-2024·2024-07-24

    IV Infusion Pump Set Backcheck Valve Malfunction Recall

    B. Braun Medical recalls Infusomat UNIV. 15 DROP PUMP SET due to backcheck valve malfunction that could cause medication backflow and loss of medication, resulting in adverse drug reactions.

    Product
    Infusomat UNIV. 15 DROP PUMP SET, 3 CARESITE, ASV-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 363433
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2391-2024·2024-07-24

    Infusomat UNIV. 15 IV Pump Set Recalled for Backflow Hazard

    B. Braun Medical is recalling 32,752 units of the Infusomat UNIV. 15 DR pump tubing set due to potential backcheck valve malfunction that could cause medication backflow between IV containers and medication loss.

    Product
    Infusomat UNIV. 15 DR PUMP SET, 1.2FIL, 2CRSTE ASV-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 363424
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2412-2024·2024-07-24

    Surgical Image Guidance Software May Cause Incorrect Toric IOL Axis Placement

    Surgical image guidance software in NGENUITY 3D systems may miscalculate lens axis placement during eye rotation, potentially causing astigmatic error and decreased visual acuity.

    Product
    Surgical Image Guidance Functionality, software used with NGENUITY 3D Visualization System, Part Number: 8065000399
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2402-2024·2024-07-24

    Outlook IV Infusion Pump Set Recalled Due to Backcheck Valve Malfunction Risk

    B. Braun is recalling Outlook IV pump sets due to potential backcheck valve malfunction that could allow medication backflow and prevent proper priming, posing a risk of adverse drug reactions and medication loss.

    Product
    Outlook OUTLOOK PUMP SET,3 CARESITE LADS,115 IN. Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/ Catalog Number: 490361
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2365-2024·2024-07-24

    Abbott Proclaim Plus 5 Pulse Generator May Have Shorter Service Life Than Labeled

    Abbott is recalling 38 Proclaim Plus 5 Implantable Pulse Generators because they may reach end of service sooner than product labeling indicates, potentially affecting pain management therapy for affected patients.

    Product
    Abbott Proclaim Plus 5 Implantable Pulse Generator, REF 3671, Sterile EO, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2385-2024·2024-07-24

    B. Braun Infusomat 60 IV Pump Sets Recalled for Backcheck Valve Malfunction

    B. Braun is recalling Infusomat 60 infusion pump sets (Model 363010) due to potential backcheck valve malfunction. The defect could cause medication to flow backward into primary IV containers and prevent proper medication delivery.

    Product
    Infusomat 60 DROP METRISET PUMP SET,3 SFLINE ASV-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 363010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2379-2024·2024-07-24

    Infusion Pump Sets Recalled for Potential Backflow of Medication

    B. Braun is recalling Infusomat UNIV. 15 IV pump sets due to a backcheck valve malfunction that could divert medication between containers and prevent proper priming.

    Product
    Infusomat UNIV. 15 DR PUMP SET, 1.2 FIL, 2 CRSITE-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication. Model/Catalog Number: 362033
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2384-2024·2024-07-24

    IV Pump Sets Recalled for Potential Backcheck Valve Malfunction

    B. Braun Infusomat SPACE IV pump sets may experience backcheck valve malfunction, causing medication backflow between containers and preventing proper IV line priming. This could result in adverse drug reactions, incorrect medication doses, or medication loss.

    Product
    Infusomat SPACE PUMP IV SET , 120 IN.- Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 362432
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2387-2024·2024-07-24

    B. Braun Infusomat SPACE IV Set Backcheck Valve Malfunction Recall

    B. Braun Medical is recalling 68,205 Infusomat SPACE IV Sets due to a potential backcheck valve malfunction that could allow medication backflow between IV containers.

    Product
    Infusomat SPACE PUMP IV SET, 2 CARESITES, ASV-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 363420
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2368-2024·2024-07-24

    Abbott Recalls Proclaim 7 Elite Pulse Generator for Battery Life Discrepancy

    Abbott Medical is recalling Proclaim 7 Elite Implantable Pulse Generators because the device may reach end of service sooner than indicated in the product labeling. Patients should consult their healthcare provider.

    Product
    Proclaim 7 Elite Implantable Pulse Generator, REF 3662, Sterile EO, Rx Only
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2377-2024·2024-07-24

    IV Infusion Set Backcheck Valve Malfunction May Cause Medication Loss

    B. Braun is recalling OUTLOOK IV Sets due to potential backcheck valve malfunction that could allow medication backflow and loss. The defect may result in adverse drug reactions or medication loss.

    Product
    OUTLOOK IV SET 15DROP W/3 CARESITE-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication. Model/Catalog Number: 354213
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2392-2024·2024-07-24

    Infusomat UNIV. 15 IV Pump Set Recalls Due to Backcheck Valve Malfunction

    B. Braun is recalling Infusomat UNIV. 15 IV pump sets because the backcheck valve may malfunction, potentially causing medication backflow or loss, which could lead to adverse drug reactions.

    Product
    Infusomat UNIV. 15 DROP PUMP SET, 3 CARESITE, ASV-Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 363430
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2400-2024·2024-07-24

    Infusomat SPACE IV Pump Set Recalled for Backcheck Valve Malfunction

    B. Braun is recalling Infusomat SPACE IV pump sets due to a backcheck valve malfunction that could cause medication to flow backward into the primary IV container and prevent proper priming of the line.

    Product
    Infusomat SPACE PUMP IV SET W/2 CARESITE, CKVLV -Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/ Catalog Number: 490103
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2410-2024·2024-07-24

    Knee Prosthesis Tibial Component Screws Cannot Be Loosened During Surgery

    The Endo Model M tibial components cannot be loosened during surgery, preventing surgeons from making necessary intraoperative adjustments. This may force unplanned procedure changes.

    Product
    Endo Model M Tibial Components Modular Knee Prosthesis System. Product codes 15-2814/01, 15-2814/02, 15-2814/03, 15-2814/04, 15-2815/11, 15-2815/12, 15-2816/11, 15-2816/12, 15-2817/11, 15-2817/12, 15-2818/11, 15-2818/12, 15-2834/01, 15-2834/02, 15-2834/03, 15-2834/04…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2407-2024·2024-07-24

    Surgical Product Recalled Due to Torn Pouches Compromising Sterile Barrier

    Ethicon Sarl is recalling SURGICEL FIBRILLAR product due to torn foil pouches that compromised the sterile barrier. Approximately 39,010 units distributed in the US, India, and Japan are affected.

    Product
    SURGICEL FIBRILLAR 1INX2IN(2.5CMX5.1CM), Product Number: 1963
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2370-2024·2024-07-24

    UNITRAX Hip Implant Head Component Recalled for Package Label Size Mismatch

    Howmedica Osteonics is recalling UNITRAX hip implant head components because the package label size may not match the device actually inside, potentially leading to incorrect surgical implantation. Affected units were distributed worldwide.

    Product
    UNITRAX Endoprosthesis Head Component - 43mm. Implantable component used in partial hip arthroplasty. Catalog Number: 6942-5-043
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2381-2024·2024-07-24

    Infusion pump set backcheck valve malfunction may prevent medication delivery

    B. Braun Medical is recalling an infusion pump set due to potential backcheck valve malfunction that could cause medication to flow backward into IV containers and prevent proper medication administration. The recall affects 3,624 units distributed worldwide.

    Product
    Infusomat UNIV. 15 DROP PUMP SET W/ 0.2 FILTER- Used with an electrically-powered infusion pump for intravenous (IV) administration of medication Model/Catalog Number: 362050
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2356-2024·2024-07-24

    Cochlear implant devices recalled for potential internal electronics substrate defect

    MED-EL Mi1250 SYNCHRONY 2 cochlear implants may have cracks in their internal electronics substrate that could cause device failure. Seven devices distributed to Durham, North Carolina are affected.

    Product
    Mi1250 SYNCHRONY 2, Item Numbers: a) 39541, FLEXSOFT S-Vector; b) 39545, FLEX28 S-Vector; c) 39547, FLEX26 S-Vector; Cochlear Implant
    Category
    Medical Device
    Distribution
    1 state