Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

6901–6925 of 40007

  • ModerateFDA (Devices)·Z-2037-2024·2024-06-19

    NEOMED Oral Syringes Recalled Over Missing Expiration Dates on Labels

    Avanos Medical is recalling NEOMED oral syringes because expiration dates were not printed on outer shipping labels, allowing expired units to reach customers.

    Product
    NEOMED* Pharmacy Syringes - Nonsterile (Non ENFit) with below product descriptions: a.0.5mL Oral Syringe Orange NonSterile, Product Code BC-S05EO; b. 12mL Oral Syringe Orange NonSterile, Product Code BC-S12EO; c. 1mL Oral Syringe Orange NonSterile, Product Code BC-S1EO;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2036-2024·2024-06-19

    NEOMED nonsterile pharmacy syringes recalled for missing expiration dates on labels

    Avanos Medical recalls NEOMED nonsterile pharmacy syringes because expiration dates were not printed on outer shipping labels, resulting in expired products being distributed.

    Product
    NEOMED* Pharmacy Syringes - Nonsterile (Non ENFit) with below product descriptions: a. 0.5mL Oral Syringe Blue NonSterile, Product Code BB-S05EO; b. 12mL Oral Syringe Blue NonSterile, Product Code BB-S12EO; c. 1mL Oral Syringe Blue NonSterile, Product Code BB-S1EO; d. 2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1920-2024·2024-06-12

    Pediatric Patient Return Electrode Recalled for Reported Patient Burns

    Megadyne Medical Products is recalling its MEGA SOFT Pediatric Patient Return Electrode due to reports of patient burns during electrosurgical use. Approximately 1,270 units distributed worldwide are affected.

    Product
    MEGADYNE MEGA SOFT Pediatric Patient Return Electrode. Reusable Patient Return Electrode for patients weighing (0.8lb-50lb), (350g-22.7Kg), 66cm Long x 30.5cm Wide x 1.25cm. Electrosurgical use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1879-2024·2024-06-12

    Arrow UltraFlex Intra-Aortic Balloon Catheter Kit Recalled for Device Malfunction

    Arrow International is recalling its UltraFlex Intra-Aortic Balloon Catheter Kit because of infrequent device malfunction that could lead to serious health consequences. 44,807 units are affected worldwide.

    Product
    Arrow UltraFlex Intra-Aortic Balloon Catheter Kit, a) REF IAB-06830-U; b) REF IAB-06840-U; c) REF IAB-06850-U
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1878-2024·2024-06-12

    Intra-Aortic Balloon Catheter Kit Recalled for Inflation and Structural Defects

    Arrow International is recalling intra-aortic balloon catheter kits due to potential inflation failure, catheter damage, and helium loss that could cause serious health consequences.

    Product
    Arrow FiberOptix Intra-Aortic Balloon Catheter Kit: a) REF IAB-05830-LWS; b) REF IAB-05840-LWS; c) REF IAB-05850-LWS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1877-2024·2024-06-12

    Sevoflurane Vaporizer Component Recall Due to Hydrogen Fluoride Degradation

    Getinge's sevoflurane vaporizer component may degrade into hydrogen fluoride, posing inhalation and skin exposure risks to healthcare workers and patients. The FDA Class I recall affects 120 units distributed across six U.S. states.

    Product
    Vaporizer Sevoflurane Maquet Filling, Product code/REF number (6682282), Component of: Flow-i C20, Flow-i C30,Flow-i C40, Flow-c, Flow-e.
    Category
    Medical Device
    Distribution
    7 states
  • SevereFDA (Devices)·Z-1880-2024·2024-06-12

    Arrow Ultra 8 Intra-Aortic Balloon Catheter Kit Recalled for Inflation Defect

    The FDA recalled 3,138 Arrow Ultra 8 intra-aortic balloon catheter kits globally due to potential balloon inflation failure and helium pathway damage that could compromise critical cardiac support.

    Product
    Arrow Ultra 8 IAB Intra-Aortic Balloon Catheter Kit, a) REF IAB-05830-U; b) REF IAB-05840-U
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1935-2024·2024-06-12

    LOSPA Patella Knee Component Recalled for Unsupported Expiration Date

    CORENTEC's LOSPA Patella Component knee implants are recalled due to an unsupported 10-year expiration date. Thirty-five units were distributed nationwide.

    Product
    LOSPA Patella Component Model/Catalog Number: 01.10.9XX Software Version: N/A Product Description: Patella
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1949-2024·2024-06-12

    Medical device recall: HA FlexTrak patient transport trolley oil leak hazard

    Philips is recalling the HA FlexTrak patient transport trolley due to potential oil leaks from the hydraulic system that create slipping and falling hazards. Approximately 100 units have been distributed worldwide.

    Product
    HA FlexTrak-Patient transport functionality to transport the patient from the preparation area to the MR system, Product Number: 989710006412
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1950-2024·2024-06-12

    Medical device trolley recalled due to oil leak causing slipping hazard

    Philips HA FlexTrak II patient transport trolleys may leak hydraulic oil onto the floor when pressed, creating a slip and fall hazard. About 590 units are affected worldwide.

    Product
    HA FlexTrak II-Patient transport functionality to transport the patient from the preparation area to the MR system, Product Number: 989710008732
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1943-2024·2024-06-12

    Arial Emergency Mobile App Restarts Cause Alert Overload and Call Failures

    The Arial mobile application experiences frequent restarts on iOS 17.4 and 17.5, causing alert overload, communication failures, and offline status in healthcare facilities.

    Product
    Arial mobile application, model numbers 54640, 54630, and 54630-SMA, that utilizes Apple iOS 17.4 and Apple iOS 17.5, a component of the Arial Emergency and Nurse Call System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2024-2024·2024-06-12

    Medline Sterile Iris Scissors Recall Due to Detachable Tip Protector

    Medline is recalling 67,811 units of sterile iris scissors because the tip protector may detach during use. The recall affects units distributed nationwide and internationally.

    Product
    MEDLINE STERILE IRIS SCISSORS CVD/STD REF DYNJ04049 (case) and DYNJ04049H (individual unit)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1942-2024·2024-06-12

    WAVi Research EEG Desktop System recalled due to FDA Warning Letter

    WAVi Co. is recalling 281 units of the WAVi Research EEG Desktop System following an FDA-issued Warning Letter. The company requested the return of components due to closure of their research study.

    Product
    WAVi Research EEG Desktop System is comprised of the WAVi Research EEG Desktop Software with Instruction Manual and Brochure, and Heart Rate Variability (HRV) Ear Clips. The system kit also incorporates use of the firm's cleared EEG analysis technology (the WAVi SCAN EEG System a
    Category
    Medical Device
    Distribution
    31 states
  • HighFDA (Devices)·Z-1937-2024·2024-06-12

    Medline Disposable Syringes Recalled for Inaccurate Volume Delivery

    Medline is recalling 25.2 million Luer Lock disposable syringes because testing documentation does not confirm they deliver accurate volumes across their claimed capacity. The inaccuracy may pose a risk to patient health.

    Product
    MEDLINE LUER LOCK DISPOSABLE SYRINGE WITHOUT NEEDLE, REF SYR101010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1971-2024·2024-06-12

    ADVANTA VXT Vascular Grafts Recalled for Slider Rod Separation

    Atrium Medical is recalling 53,308 ADVANTA VXT vascular grafts worldwide due to reported separation of the slider rod from the swivel core, with a gap observed between the components.

    Product
    ADVANTA VXT, 6X80, 1GDS, FH, STR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2011-2024·2024-06-12

    Vascular Graft Component Separation Risk Triggers Worldwide Device Recall

    Atrium Medical recalls FLIXENE vascular grafts due to reported separation of the Swivel Rod from the Swivel Core, creating gaps that could affect device function. Over 53,000 units worldwide are affected.

    Product
    FLIXENE, 6X30, 1GDS, STR. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1951-2024·2024-06-12

    FDA Recalls Atrium Medical Vascular Graft for Slider Separation Defect

    Atrium Medical is recalling ADVANTA VXT vascular grafts due to reports of the slider rod separating from the swivel core, which could impair proper device function.

    Product
    ADVANTA VXT, 5X40, 1GDS, NH, STR-SW. Single-Ended Slider. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1999-2024·2024-06-12

    Vascular Graft Swivel Rod Separation Reported in ADVANTA VXT Devices

    Atrium Medical recalls ADVANTA VXT vascular grafts due to reported separation of the slider swivel rod from its core, creating a gap between components. No injuries reported.

    Product
    ADVANTA VXT, 4-7X45, 1GDS, CH, TPR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1964-2024·2024-06-12

    Vascular Graft Component Separation Recall from Atrium Medical

    Atrium Medical is recalling 53,308 ADVANTA VXT vascular grafts due to reports of Slider GDS Swivel Rod separation from the Swivel Core. Component separation could compromise device function.

    Product
    ADVANTA VXT, 5X50, 1GDS, FH, STR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1986-2024·2024-06-12

    Vascular graft component separation reported in Advanta VXT devices

    Atrium Medical Corporation recalls Advanta VXT vascular grafts due to separation of internal swivel components. Approximately 53,308 units worldwide are affected, with the slider GDS swivel rod potentially separating from its core.

    Product
    ADVANTA VXT, 6X70, 1GDS, FH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2025-2024·2024-06-12

    Bedside Monitor Software Issue Causes False Oxygen Saturation Probe Failure Alarms

    Nihon Kohden's BSM-3000 Series Bedside Monitors may produce false SpO2 probe failure alarms due to a software issue. Healthcare facilities should contact the manufacturer for guidance.

    Product
    BSM-3000 Series Bedside Monitor REF BSM-3572A The Life Scope BSM-3000 Series Bedside Monitoring System is intended to monitor, display and record physiological data to provide cardiac and vital signs monitoring within a medical facility.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1953-2024·2024-06-12

    Vascular Graft Device Recalled for Slider Component Separation

    Atrium Medical Corporation is recalling ADVANTA VXT vascular grafts due to reported separation of the slider component from the swivel core. The recall affects 53,308 units worldwide.

    Product
    ADVANTA VXT, 8X40, 1GDS, NH, STR-SW. Single-Ended Slider. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1952-2024·2024-06-12

    Vascular graft recall: Advanta VXT swivel rod separation

    Atrium Medical recalls Advanta VXT vascular grafts due to swivel rod separation from the core component. Approximately 53,308 units are affected worldwide.

    Product
    ADVANTA VXT, 6X40, 1GDS, NH, STR-SW. Single-Ended Slider. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1965-2024·2024-06-12

    Vascular Graft Recall Due to Swivel Rod Separation

    Atrium Medical is recalling the ADVANTA VXT vascular graft due to reported separation of the Slider GDS Swivel Rod from the Swivel Core. This component separation could affect device function.

    Product
    ADVANTA VXT, 6X50, 1GDS, FH, STR-SW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1980-2024·2024-06-12

    Vascular Graft Recall for Component Separation in ADVANTA VXT

    Atrium Medical is recalling ADVANTA VXT vascular grafts due to reported separation of the Slider GDS Swivel Rod from the Swivel Core. This component separation could compromise device function.

    Product
    ADVANTA VXT, 6X80, 1GDS, NH, STR-TW. Single-Ended Slider GDS. Vascular graft
    Category
    Medical Device
    Distribution
    Distributed nationwide