The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

8701–8725 of 13683

  • HighFDA (Devices)·Z-2242-2023·2023-08-02

    Hernia repair mesh balloon may not inflate during surgery

    Davol Ventralight ST hernia repair mesh balloons may fail to inflate during surgery, potentially causing inadequate mesh placement, infection, and procedure delays.

    Product
    Ventralight ST 4.5" Circle with Echo PS- A low profile, bioresorbable, coated, permanent mesh, with a pre-attached removable positioning system, designed for the reconstruction of soft tissue deficiencies during laparoscopic ventral hernia repair. Catalog Number: 5955450
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2229-2023·2023-08-02

    Flexiva Pulse 242 Laser Fibers Recalled Due to Overheating Risk

    Boston Scientific's Flexiva Pulse 242 TracTip laser fibers may overheat during use due to a manufacturing defect, posing a burn risk. Affected units should not be used.

    Product
    Flexiva Pulse 242 TracTip Single-Use Laser Fibers - intended to be used as a device that transmits Ho:YAG laser energy from cleared laser consoles to urological anatomy Single-pack UPN : M006L8405960
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2238-2023·2023-08-02

    FRED Flow Re-Direction Endoluminal Device recalled for incorrect inner stent length

    The FDA is recalling FRED Flow Re-Direction Endoluminal Devices due to a manufacturing defect that may result in incorrect inner stent length, potentially affecting device performance. 474 units were affected.

    Product
    FRED Flow Re-Direction Endoluminal Device, REF: FRED3507-PMA, FRED3511, FRED3511-PMA, FRED3516-CA, FRED3516-PMA, FRED3524, FRED3524-CA, FRED3524-PMA, FRED3536-CA, FRED3536-PMA, FRED4007-PMA, FRED4012-CA, FRED4012-PMA, FRED4017-PMA, FRED4026, FRED4026-PMA, FRED4038-PMA, FRED4508,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2235-2023·2023-08-02

    vRad PACS medical imaging system recalled for intermittent image display failures

    Virtual Radiologic's vRad PACS with Mammography system may intermittently fail to display radiology images, preventing radiologists from viewing diagnostic studies. Eight units across seven U.S. states are affected by this Class II recall.

    Product
    vRad PACS with Mammography
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2239-2023·2023-08-02

    Argon Medical Option Elite Vena Cava Filter Recall Due to Performance Risk

    Argon Medical Devices is recalling 3 Option Elite Retrievable Vena Cava Filters due to a potential performance defect that could result in pulmonary embolism. Affected units were distributed in Texas.

    Product
    Argon Medical Devices, REF 352506070E, Option Elite Retrievable Vena Cava Filter, Suitable of Jugular or Femoral Delivery, STERILEO, RxOnly, CE 2797
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2234-2023·2023-08-02

    Laser fiber medical devices recalled for potential burn injury hazard

    Boston Scientific recalls Flexiva Pulse laser fibers due to manufacturing defects that can cause fiber connector overheating and potential burns if touched. Affects 280 units in US and Canada.

    Product
    Flexiva Pulse ID 242 TracTip single Use Fiber-intended to be used as a device that transmits Ho:YAG laser energy from cleared laser consoles to urological anatomy 5-pack UPN: M006L8406961
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2228-2023·2023-08-02

    Flexiva Pulse 242 Laser Fibers Recalled Due to Overheating Risk

    Boston Scientific is recalling Flexiva Pulse 242 Single-Use Laser Fibers due to manufacturing defects that reduce power output and aiming beam visibility, risking fiber connector overheating and potential burns.

    Product
    Flexiva Pulse 242 Single-Use Laser Fibers-intended to be used as a device that transmits Ho:YAG laser energy from cleared laser consoles to urological anatomy. Single-pack UPN : M006L8405910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2236-2023·2023-08-02

    Trexo Device recalled due to electrical hazards and burn risk

    Trexo Robotics is recalling the Trexo Device due to electrical issues that could cause burns, device malfunction, and electromagnetic interference with other equipment. Consumers should stop using affected devices.

    Product
    Trexo Device
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2231-2023·2023-08-02

    Flexiva Pulse ID Laser Fiber Recalled for Incorrect Component

    Boston Scientific is recalling Flexiva Pulse ID laser fibers due to an incorrect component that reduces power output and aiming beam brightness. The component can overheat, risking burns to users who touch the fiber connector.

    Product
    Flexiva Pulse ID-intended to be used as a device that transmits Ho:YAG laser energy from cleared laser consoles to urological anatomy Single-pack UPN: M006L8406910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2246-2023·2023-08-02

    COVID-19 Diagnostic Test Kits Recalled Due to Performance Reliability Issues

    Qiagen has recalled 4155 QIAstat-Dx Respiratory SARS-CoV-2 Panel kits due to decreased performance reliability. Test failures (run abortions) may require samples to be retested, potentially delaying diagnosis.

    Product
    QIAstat-Dx Respiratory SARS-CoV-2 Panel (V1 and V2, CE IVD, not US IVD, not sold in the US.) Qualitative test intended for analyzing nasopharyngeal swab (NPS) samples from patients suspected of respiratory infection REF: 691214
    Category
    Medical Device
    Distribution
    14 states
  • ModerateFDA (Devices)·Z-2225-2023·2023-08-02

    Diagnostic Verification Product May Not Meet Shelf Life Stability Specifications

    Ortho-Clinical Diagnostics is recalling VITROS NT-proBNP II Range Verifiers Lot 0090 because the product may not meet shelf life stability specifications. Used for diagnostic system calibration verification.

    Product
    VITROS Immunodiagnostic Products NT-proBNP II Range Verifiers-For in vitro diagnostic use only. For use in verifying the calibration range of the VITROS ECi/ECiQ/3600 Immunodiagnostic Systems and the VITROS 5600/XT 7600 Integrated Systems when used for the quantitative measuremen
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2226-2023·2023-08-02

    A901 Communication Manager Software Update Not Available for Intellis System

    The A901 Communication Manager application did not receive a timely update to match the A710 Clinician Programmer software release for Intellis Neurostimulation Systems, creating a version mismatch.

    Product
    A901 Communication Manager Application, used in conjunction with the A710 Clinician Programmer application..
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-2016-2023·2023-07-26

    Olympus Bronchovideoscope Recalled for Endobronchial Combustion Risk

    Olympus is recalling 17,609 bronchovideoscope units nationwide due to complaints of endobronchial combustion during therapeutic laser procedures, which poses a fire and burn risk to patients.

    Product
    Olympus EVIS EXERA II BRONCHOVIDEOSCOPE BF TYPE, Model Numbers BF-P180, BF-Q180, BF-Q180-AC, BF-1T180, BF-1TQ180
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2151-2023·2023-07-26

    Cardiosave Hybrid Intra-Aortic Balloon Pump recalls due to unexpected device shutdown

    Datascope has recalled Cardiosave Hybrid IABP models due to tantalum capacitor failures that may cause unexpected device shutdown, interrupting life-critical cardiac therapy.

    Product
    Cardiosave Hybrid Intra-Aortic Balloon Pump (IABP), Model numbers 0998-00-0800-31 0998-00-0800-32 0998-00-0800-33 0998-00-0800-34 0998-00-0800-35 0998-00-0800-45 0998-00-0800-52 0998-00-0800-53 0998-00-0800-55 0998-00-0800-65 0998-UC-0800-31* 0998-UC-0800-33* 0998
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2149-2023·2023-07-26

    Cardiosave Hybrid IABP may fail to charge batteries, interrupting therapy

    The Cardiosave Hybrid Intra-Aortic Balloon Pump may lose the ability to charge batteries in one or both bay slots, potentially interrupting critical therapy if disconnected from AC power. Low battery alarms may alert users before therapy is interrupted.

    Product
    Cardiosave Hybrid Intra-Aortic Balloon Pump (IABP), Model numbers 0998-00-0800-31 0998-00-0800-32 0998-00-0800-33 0998-00-0800-34 0998-00-0800-35 0998-00-0800-45 0998-00-0800-52 0998-00-0800-53 0998-00-0800-55 0998-00-0800-65 0998-UC-0800-31* 0998-UC-0800-33* 0998
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2114-2023·2023-07-26

    Abiomed Impella 5.5 pump recalled due to impeller blade damage risk

    Abiomed is recalling the Impella 5.5 with SmartAssist pump due to a risk of impeller blade destruction when used with aortic valve replacement devices. Damage can result in low blood flow and systemic embolization, where broken pump pieces may enter the bloodstream.

    Product
    Impella 5.5 with SmartAssist intravascular micro axial blood pump, Product Numbers 0550-0008 and 1000100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2013-2023·2023-07-26

    Olympus Bronchoscope Recall: Risk of Combustion During Laser Procedures

    Olympus is recalling 9 bronchoscopes (Models BF-P150 and BF-1T150) due to complaints of endobronchial combustion during therapeutic laser procedures. The defect could cause fire and serious burn injuries.

    Product
    Olympus BRONCHOVIDEOSCOPE BF Type, Model Numbers BF-P150, BF-1T150
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2112-2023·2023-07-26

    Impella 5.0 Blood Pump Recalled for Potential Impeller Blade Destruction Risk

    Abiomed's Impella 5.0 intravascular blood pump is recalled due to risk of impeller blade destruction when interacting with heart valve replacements. The damaged pump can cause reduced blood flow and potentially release fractured material into the bloodstream.

    Product
    Impella 5.0 intravascular micro axial blood pump, Product Number 005062
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2113-2023·2023-07-26

    Impella LD cardiac pump recalled for impeller damage and embolization risk

    Abiomed recalls Impella LD blood pumps due to potential interaction with aortic valve replacement devices that can damage the pump impeller and cause blood clots. Patients with these devices should contact their healthcare provider.

    Product
    Impella LD intravascular micro axial blood pump, Product Number 005082
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2150-2023·2023-07-26

    Intra-Aortic Balloon Pump may fail to charge batteries, interrupting therapy

    The Cardiosave Rescue Intra-Aortic Balloon Pump may lose battery charging ability in one or both bays, potentially interrupting therapy if disconnected from power. Low battery alarms may alert users before therapy stops.

    Product
    Cardiosave Rescue Intra-Aortic Balloon Pump (IABP), Model numbers 0998-00-0800-75 0998-00-0800-83 0998-00-0800-85
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2116-2023·2023-07-26

    Impella CP cardiac pump recalls due to motor housing interaction with stents

    Abiomed is recalling Impella CP with SmartAssist blood pumps due to risk of motor housing interaction with transcatheter aortic valve replacement devices, which can damage the pump's impeller blades and reduce blood flow.

    Product
    Impella CP with SmartAssist intravascular micro axial blood pump, Product Numbers 0048-0024, 0048-0045, 1000080
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2115-2023·2023-07-26

    Impella CP Blood Pump Recalled for Blade Destruction From Stent Interaction

    Abiomed's Impella CP cardiac pump can be damaged by interaction with replacement heart valves, potentially causing blood clots. The FDA classified this as a Class I recall of 9,252 units worldwide.

    Product
    Impella CP intravascular micro axial blood pump, Product Number 0048-0032
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2012-2023·2023-07-26

    Olympus Bronchofiberscope BF Type recalled for combustion risk during laser procedures

    Olympus bronchoscopes (Models BF-PE2 and BF-TE2) are recalled due to reports of combustion inside the airway during laser-assisted medical procedures. This is an FDA Class I recall.

    Product
    Olympus BRONCHOFIBERSCOPE BF Type, Model Numbers BF-PE2, BF-TE2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2015-2023·2023-07-26

    Olympus BRONCHOVIDEOSCOPE Model BF-Q170 Recalled Due to Combustion Risk

    Olympus BRONCHOVIDEOSCOPE Model BF-Q170 is recalled nationally due to complaints of endobronchial combustion during therapeutic laser procedures, classified as FDA Class I.

    Product
    Olympus BRONCHOVIDEOSCOPE, Model Numbers BF-Q170
    Category
    Medical Device
    Distribution
    Distributed nationwide