The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

11101–11125 of 13731

  • HighFDA (Devices)·Z-1725-2022·2022-09-21

    GXL Acetabular Hip Implant Liners Recalled Due to Packaging Defect

    Exactech is recalling specific GXL acetabular hip implant liners due to non-conforming packaging that may cause accelerated device wear. The recall affects 1,017 devices distributed worldwide.

    Product
    GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. 0 DEG ACUMATCH CONSTRAINED LINER SZ E 28MM ID, REF 144-28-05; b. 0 DEG ACUMATCH CONSTRAINED LINER SZ F 28MM ID, REF 144-28-06; c. 0 DEG ACUMATCH CONSTRAINED LINER SZ G 28MM ID, REF 144-28-07
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1726-2022·2022-09-21

    GXL Acetabular Liners Recalled Due to Improper Packaging and Accelerated Wear

    Exactech is recalling 136 GXL acetabular liners used in hip implants due to non-conforming packaging that may cause accelerated wear. The devices were distributed worldwide to multiple countries.

    Product
    GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. ACUMATCH 15 DEGREE LINER 22MM SZ C, REF 132-22-03 b. ACUMATCH 15 DEGREE LINER 28MM SZ D, REF 13-28-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1720-2022·2022-09-21

    ICU Medical Infusion Extension Set Recall Due to Connector Housing Gap

    ICU Medical recalls 5.8 million infusion extension sets due to a manufacturing defect that creates a visible gap in the connector housing, potentially compromising device integrity.

    Product
    8.5" (22 cm) Appx 0.85 ml, Bifuse Pressure Infusion (400 psig) Ext Set w/2 Remv MicroClave Clear, 2 Purple Clamps, Rotating Luer;
    Category
    Medical Device
    Distribution
    51 states
  • HighFDA (Devices)·Z-1717-2022·2022-09-21

    Roadrunner UniGlide Vascular Wire Guide Recalled for Sterility Compromise

    Cook Incorporated is recalling 30 units of Roadrunner UniGlide Hydrophilic Wire Guides due to packaging failure that may compromise device sterility.

    Product
    Roadrunner UniGlide Hydrophilic Wire Guide REFERENCE PART NUMBER (RPN): HPWS-35-150 ORDER NUMBER (GPN): G56152. For vascular catheter positioning and exchange in diagnostic and interventional procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1711-2022·2022-09-21

    Vascular Wire Guide Recalled for Potential Sterility Compromise

    Cook Incorporated is recalling the Roadrunner UniGlide Hydrophilic Wire Guide due to failed packaging testing that may compromise device sterility. The affected lot numbers are 14095646 and 14174879.

    Product
    Roadrunner UniGlide Hydrophilic Wire Guide REFERENCE PART NUMBER (RPN): HPWA-18-150 ORDER NUMBER (GPN):G56161. For vascular catheter positioning and exchange in diagnostic and interventional procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1750-2022·2022-09-21

    Surpria 64 Software Error May Prevent Image Reconstruction During Scanning

    Surpria 64 CT scanner software versions V3.11 and V3.22 may encounter errors that prevent image reconstruction, requiring repeat scans that expose patients to additional radiation. 16 units nationwide are affected.

    Product
    Surpria 64: Software Version V3.11, V3.22
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1715-2022·2022-09-21

    Vascular catheter wire guide recalled for sterility testing failure

    Cook Incorporated is recalling Roadrunner UniGlide Hydrophilic Wire Guides due to packaging testing failures that may compromise device sterility. The recall affects 865 units distributed nationwide and internationally.

    Product
    Roadrunner UniGlide Hydrophilic Wire Guide REFERENCE PART NUMBER (RPN): HPWAS-35-150 ORDER NUMBER (GPN): G56176. For vascular catheter positioning and exchange in diagnostic and interventional procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1734-2022·2022-09-21

    GXL Acetabular Liners Packaging Defect May Cause Accelerated Wear

    Exactech GXL acetabular hip implant liners in non-conforming bags may experience accelerated wear. Approximately 7,946 devices were distributed worldwide. No injuries have been reported.

    Product
    GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. ACUMATCH 0 DEGREE LINER 28MM 46MM, REF 130-28-05; b. ACUMATCH 0 DEGREE LINER 28MM 48MM, REF 130-28-06; c. ACUMATCH 0 DEGREE LINER 28MM 50/52MM, REF 130-28-07; d. ACUMATCH 0 DEGREE LINER 28
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1713-2022·2022-09-21

    Vascular wire guides recalled due to potential sterility compromise

    Cook Incorporated is recalling 5,400 Roadrunner UniGlide Hydrophilic Wire Guides because the devices failed packaging tests required to verify sterility. The affected devices are used in diagnostic and interventional vascular procedures.

    Product
    Roadrunner UniGlide Hydrophilic Wire Guide REFERENCE PART NUMBER (RPN): HPWA-35-150 ORDER NUMBER (GPN): G56173. For vascular catheter positioning and exchange in diagnostic and interventional procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1721-2022·2022-09-21

    Extension Set Recall Due to Connector Housing Manufacturing Defect

    ICU Medical is recalling bifurcated extension sets used in medical infusions. The sets have a manufacturing defect causing visible gaps in the connector housing, affecting millions of units distributed in the U.S. and internationally.

    Product
    6.5" (17 cm) Appx 0.84 ml, Smallbore Bifuse Ext Set w/2 MicroClave Clear, 2 Check Valves, Luer Lock;
    Category
    Medical Device
    Distribution
    51 states
  • HighFDA (Devices)·Z-1719-2022·2022-09-21

    Medical connector recalled due to manufacturing housing gap defect

    ICU Medical is recalling MicroClave Clear Neutral Connectors used in intravascular catheters due to a manufacturing defect that creates a visible gap between housing parts.

    Product
    MicroClave Clear Neutral Connector. A bidirectional connector used as an accessory to an intravascular catheter placed in the vein or artery.
    Category
    Medical Device
    Distribution
    51 states
  • HighFDA (Devices)·Z-1722-2022·2022-09-21

    ICU Medical Recalls Intravascular Connectors for Manufacturing Defect

    ICU Medical is recalling approximately 5.8 million MicroClave Clear Connectors used in IV administration due to a manufacturing defect that creates a visible gap between the connector housing.

    Product
    MicroClave Clear Neutral Connector; MicroClave Clear Connector; MicroClave Clear Neutral Connector, Approx Priming Volume: 0.04 mL. Accessory for Intravascular Administration Set
    Category
    Medical Device
    Distribution
    51 states
  • HighFDA (Devices)·Z-1730-2022·2022-09-21

    GXL Acetabular Liners Recalled Due to Non-Conforming Packaging and Accelerated Wear Risk

    Exactech's GXL acetabular hip implant liners are being recalled because they were packaged in non-conforming bags that may cause accelerated wear of the devices.

    Product
    GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. NOVATION CONSTRAINED LINER 28MM ID GROUP 1, REF 134-28-41 b. NOVATION CONSTRAINED LINER 32MM ID GROUP 2, REF 134-32-42 c. NOVATION CONSTRAINED LINER 36MM ID GROUP 3, REF 134-36-43 d.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1751-2022·2022-09-21

    iSED Tubing Spare Part Recalled for Potential Biohazard Leak Risk

    Alcor Scientific is recalling iSED Primary Pump Tubing Spare Part Kits due to potential biohazard leak from the Probe Tube when installed on the iSED ESR Analyzer. Affected lot (4/22) includes 38 units distributed nationwide and internationally.

    Product
    iSED Primary Pump Tubing Spare Part Kit- (IVD) tubing is used to move sample and wash solution from the aspiration needle, through the reading chamber, and to the waste on the iSED Automated ESR Analyzer PN: 112-13-002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1745-2022·2022-09-21

    INOmax DSIR Delivery System incompatible with upgraded Leoni Plus ventilator

    The INOmax DSIR nitric oxide delivery system is incompatible with the 2021-upgraded Leoni Plus ventilator. Without proper connection including a required one-way valve, patients may receive excessive nitric oxide.

    Product
    INOmax DSIR -(delivery system) delivers INOMAX (nitric oxide for inhalation) therapy gas into the inspiratory limb of the patient breathing circuit in a way that provides a constant concentration of nitric oxide (NO), as set by the user, Model Number: 10007
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1748-2022·2022-09-21

    SCENARIA View software error may require additional patient radiation exposure

    SCENARIA View imaging software errors prevent image reconstruction, which may require additional scans and expose patients to unnecessary radiation.

    Product
    SCENARIA View: Software Version V1.08, V1.09B, V1.09C, V1.09D, V1.0B, V1.0C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1741-2022·2022-09-21

    PTS Panels CHOL+GLU Test Strips Recalled for Incorrect Instructions

    PTS Panels CHOL+GLU Test Strips (lot A202) are recalled because incorrect instructions for use were packaged with the product. Distribution includes the US, Japan, and Russia.

    Product
    PTS Panels CHOL+GLU Test Strips (REF 1765)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1736-2022·2022-09-21

    Steris SixCess Challenge Pack Recalled for Incorrect Chemical Indicators

    Steris Corporation is recalling 619 boxes of Verify SixCess Challenge Pack due to incorrect chemical indicators in the packaging. This sterilization validation device is distributed across 31 U.S. states.

    Product
    Verify SixCess Challenge Pack. Used to confirm that critical parameters of steam sterilization have been reached within a challenging test pack design.
    Category
    Medical Device
    Distribution
    31 states
  • ModerateFDA (Devices)·Z-1735-2022·2022-09-21

    Stryker USB Converter in Mako Robotic Surgery System May Fail

    Mako Surgical Corporation is recalling certain Stryker USB Converter components that may arrive non-functional or fail during use. Affected units are in Illinois and Arizona.

    Product
    Stryker USB Converter, Polaris Spectra Camera, Catalog #201148, a component of the Mako Robotic-Arm Assisted Surgery System.
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Devices)·Z-1729-2022·2022-09-21

    GXL Acetabular Liners Recalled Due to Non-Conforming Packaging

    Exactech is recalling certain GXL acetabular liners packaged in non-conforming bags that may cause accelerated wear of the hip implant component. No injuries have been reported.

    Product
    GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. NOVATION GXL LINER, NEUTRAL, 28MM ID, GROUP 1 CUPS, REF 130-28-51 b. NOVATION GXL LINER, NEUTRAL, 32MM ID, GROUP 2 CUPS, REF 130-32-52 c. NOVATION GXL LINER, NEUTRAL, 36MM ID, GROUP 3 CUPS, RE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1733-2022·2022-09-21

    GXL Hip Implant Liners Recalled for Packaging Defect Risk

    Exactech is recalling specific GXL acetabular polyethylene hip implant liners because non-conforming packaging may cause accelerated wear. The company has distributed 4,956 affected devices worldwide.

    Product
    GXL acetabular liners, orthopedic hip implant component. Product Line Numbers: a. ALL POLYETHYLENE ACETABULAR CUP, CEMENTED 22MM SZ 42, REF 106-22-42; b. ALL POLYETHYLENE ACETABULAR CUP, CEMENTED 22MM SZ 44, REF 106-22-44; c. ALL POLYETHYLENE ACETABULAR CUP, CEMENTED 2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1740-2022·2022-09-21

    Helix Elite SARS-CoV-2 Reference Standard Recalled for Unregistered UK Distribution

    Microbiologics Inc. has recalled Helix Elite Inactivated SARS-CoV-2 reference standards distributed to the United Kingdom because the product was not registered for use in that region.

    Product
    Helix Elite Inactivated Standard, labeled as: a. Inactivated SARS-CoV-2 B.1.1.7 Whole Virus, REF HE0071N; b. Inactivated SARS-CoV-2 B.1.351 Whole Virus, REF HE0073N
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1659-2022·2022-09-14

    Philips OmniLab ventilator recalled for motor assembly plastic off-gassing defect

    Philips Respironics is recalling OmniLab Advanced + ventilators due to motor assemblies manufactured with nonconforming plastic that releases volatile organic compounds (VOCs). The 8 affected units were distributed across the US and internationally.

    Product
    Philips OmniLab Advanced + with Heated Tube Humidifier, Rx Only. To provide noninvasive ventilation support for patients with obstructive sleep apnea syndrome (OSA) and respiratory insufficiency.
    Category
    Medical Device
    Distribution
    42 states
  • SevereFDA (Devices)·Z-1656-2022·2022-09-14

    Philips BiPAP V30 Auto Respirators Recalled for VOC Off-Gassing Risk

    Philips Respironics recalls 295 BiPAP V30 Auto respiratory devices due to motor assemblies with nonconforming plastic. These assemblies off-gas volatile organic compounds (VOCs) during device operation.

    Product
    Philips BiPAP V30 Auto, Rx Only. To provide noninvasive ventilation support for patients with obstructive sleep apnea syndrome (OSA) and respiratory insufficiency.
    Category
    Medical Device
    Distribution
    42 states