The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

3826–3850 of 13526

  • HighFDA (Devices)·Z-1203-2025·2025-02-26

    Dexcom G6 glucose receiver may fail to deliver high or low alarms

    Under rare conditions, the Dexcom G6 receiver may fail to send high or low glucose alarms due to a software error, potentially delaying detection of dangerous blood sugar levels.

    Product
    Dexcom G6, Continuous Glucose Monitoring System, REF: STK-OR-001
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1175-2025·2025-02-26

    3M Prevena Plus Negative Pressure Therapy System Recalled for Leak Alarm Malfunctions

    KCI USA is recalling 3M Prevena Plus wound therapy systems due to complaints about malfunctioning leak alarms. The recall affects 135,268 units distributed worldwide.

    Product
    3M Prevena Plus 125 Therapy Unit and System Kits REF: PRE3021US Prevena Plus Duo Peel and Place 20cm System Kit, US PRE3201US Prevena Plus Peel and Place 35 cm system Kit, US PRE3201 Prevena Plus Peel and Place 35 cm system Kit PRE4000US Prevena Plus 125 Therapy Unit, U
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1172-2025·2025-02-26

    Augustine HotDog Return Electrode connector cables trigger contact error

    Augustine Surgical Inc. is recalling HotDog Return Electrode connector cables (Model A138) that display a 'Check Neutral Electrode Contact' error message. The recall affects 7 units distributed to Alabama, Texas, and Nevada.

    Product
    Augustine Surgical Inc. HotDog Return Electrode accessory connector cables, Model A138 used in conjunction with Warming Blankets and Mattresses.
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-1174-2025·2025-02-26

    DeRoyal AMG Suction Connector Tubing connection may fail to seal

    DeRoyal Industries is recalling AMG Suction Connector Tubing because the connection between the tubing and suction device may not seal properly, potentially affecting patient care.

    Product
    DeRoyal AMG Suction Connector Tubing REF: 71-2083, 71-C506, 71-C510, 71-C512, 71-C520, Tubing is intended for fluid movement
    Category
    Medical Device
    Distribution
    21 states
  • HighFDA (Devices)·Z-1193-2025·2025-02-26

    RayStation radiation therapy software recall for density calculation inconsistency

    RayStation treatment planning software versions 4.5-2024B contain a calculation error in density uncertainty functions affecting proton and light ion treatment plans. The error could lead to incorrect dose calculations.

    Product
    Brand Name: RayStation- Intended as a Radiation Therapy Treatment Planning System Model/Catalog Number: 6.0.0.24 Software Version: RayStation 6
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1074-2025·2025-02-19

    Sevoflurane Vaporizer Quik-Fil Recalled Due to Chemical Degradation Risk

    A sevoflurane vaporizer component may degrade to hydrogen fluoride, causing respiratory damage and chemical burns to patients and workers. FDA classified this Class I recall affecting six units in Kentucky and Connecticut.

    Product
    Vaporizer Sevoflurane, Quik-Fil. Model Number: 6682285. Device is a component of Flow-i C20, Flow-i C30, Flow-i C40, Flow-c, Flow-e. For use during anesthesia.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1116-2025·2025-02-19

    Wheelchair Speed Control Remote Recalled Due to Loss-of-Control Risk

    The Smart Drive MX2+ SpeedControl Dial remote is being recalled due to a faulty circuit board that could cause loss of control of the wheelchair power assist, potentially resulting in injury.

    Product
    Max Mobility/Permobil Smart Drive MX2+ SpeedControl Dial Ref: MX2-3DC use in conjunction with the SmartDrive MX2+ Wheelchair Power Assist component.
    Category
    Medical Device
    Distribution
    52 states
  • SevereFDA (Devices)·Z-1071-2025·2025-02-19

    Olympus Guide Sheath Kits recalled for potential radiopaque tip detachment

    Olympus Single Use Guide Sheath Kits (models K-201 through K-204) are recalled because the radiopaque tip of the guide sheath may detach and fall into the patient during respiratory procedures.

    Product
    Olympus Single Use Guide Sheath Kits with the following product descriptions and model numbers: 1. Single Use Guide Sheath Kit K-201 2.0MM Channel Set: Guide Sheath, Biopsy Forceps, Cytology Brush; Model Number: K-201 2. Single Use Guide Sheath Kit K-202 2.0MM Channel Set:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1117-2025·2025-02-19

    Wheelchair Power Assist Speed Control Dial Recalled for Loss of Control Risk

    Max Mobility Smart Drive MX2+ SpeedControl Dial wheelchairs are being recalled due to faulty circuit boards that may cause loss of device control, potentially resulting in injury to users.

    Product
    Max Mobility/Permobil Smart Drive MX2+ SpeedControl Dial Ref: MX2-3DCK use in conjunction with the SmartDrive MX2+ Wheelchair Power Assist component.
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-1138-2025·2025-02-19

    Stryker Precision Thin Blade Attachments Recalled for Measurement Failure

    Stryker Corporation is recalling 622 units of Precision Thin blade attachments that may be out of measurement specifications, preventing them from fitting securely into compatible handpieces.

    Product
    stryker Precision Thin, Catalog Number REF 2296-003-108; Micro Oscillating and Sagittal Blades
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1135-2025·2025-02-19

    Cardinal Health Presource surgical kits recalled for endotoxin contamination risk

    Cardinal Health is recalling Presource Kits for potential endotoxin contamination in non-sterile surgical strips and patties. These surgical components could pose infection risks if used in procedures.

    Product
    Cardinal Health Presource Kits: 1) CHI STD SPINE OPTION 1, Catalog Number:CHIP99SP11; 2) CHI STD SPINE OPTION 1, Catalog Number:CHIP99SP12 3) CHI STD SPINE OPTION 1, Catalog Number:CHIP99SP13 4) CHI STD SPINE OPTION 1, Catalog Number:CHIP99SP1E 5) CHI STD SPINE OPTION 2, Catalog
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1122-2025·2025-02-19

    BD Pyxis MedStation ES Medication Cabinet Drawer and Door Failures Recalled

    The FDA is recalling BD Pyxis MedStation ES medication cabinets due to potential drawer and door failures that could delay medication access. Affected healthcare facilities should check their devices and contact the manufacturer if malfunctions occur.

    Product
    BD Pyxis MedStation ES (Med ES Main) REF: 323. Intended to securely store and dispense medications to a qualified and authorized healthcare provider.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1131-2025·2025-02-19

    Cardinal Health Laryngoscopy Packs Recalled for Potential Endotoxin Contamination

    Cardinal Health Presource Kits containing laryngoscopy packs are being recalled due to potential endotoxin contamination in non-sterile surgical strips and patties.

    Product
    Cardinal Health Presource Kits: 1) LARYNGOSCOPY PACK, Catalog Number:SRIET0979N;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1141-2025·2025-02-19

    Spore Test Monitoring System Printing Error May Cause Result Misdirection

    HF Acquisition Co LLC is recalling Bio52 and Bio12 HealthFirst Mail In Monitoring Systems (4,021 units) due to a printing error on return envelopes that may cause spore test results to be reported to incorrect customer accounts.

    Product
    Biological, Bio52 HealthFirst Mail In Monitoring System, 52 Tests, Item: 1003600. Biological, Bio12 HealthFirst Mail In Monitoring System, 12 Tests, Item: 1003580
    Category
    Medical Device
    Distribution
    50 states
  • HighFDA (Devices)·Z-1121-2025·2025-02-19

    LVIS Intraluminal Support Device May Fail to Deploy Properly

    MicoVention Terumo LVIS stent devices may fail to advance from the introducer due to PTFE material on the stent loop. Eleven units (Lot 0000456768) distributed in China are affected.

    Product
    MicoVention Terumo, LVIS Intraluminal Support Device, REF: 213522-CAS, od, 3.5 mm, TL 22 mm, WL 18 mm, Sterile R, CE0297. The intended purpose of the LVIS Device is to serve as a stent-assisted coiling (SAC) device providing support to the embolic coils used in the treatment of
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1167-2025·2025-02-19

    Exactech Alteon XLE Hip Replacement Liners Recalled for Missing Barrier Layer

    Exactech is recalling Alteon XLE hip replacement liners due to a manufacturing defect. Some units lack the Ethylene Vinyl Alcohol barrier layer required for proper device function.

    Product
    Alteon XLE Item Number / Product Description: 140-22-70 NV EHXL NTL LNR G00 22MM 140-28-50 NV EHXLNTRL LNR G0 28MM 140-28-51 NV EHXLNTRL LNR G1 28MM 140-28-52 NV EHXL NTRL LNR G228MM 140-32-51 NV EHXL NTRL LNR G132MM 140-32-52 NV EHXL NTRL LNR G232MM 140-32-53 NV EHXL N
    Category
    Medical Device
    Distribution
    22 states
  • HighFDA (Devices)·Z-1129-2025·2025-02-19

    Cardinal Health Presource Surgical Kits Recalled for Endotoxin Contamination

    Cardinal Health Presource Kits may contain endotoxin-contaminated non-sterile surgical strips and patties. These kits are used in surgical procedures and have been distributed worldwide including the US, Canada, and Saudi Arabia. Affected facilities should verify lot numbers against the recall list.

    Product
    Cardinal Health Presource Kits: 1) KIT, CAROTID ENDARTERECTOMY, Catalog Number:PVV20110B; 2) KIT, CAROTID ENDARTERECTOMY, Catalog Number:PVV20110D 3) KIT,CAROTID ENDARTERECTOMY, Catalog Number:PVV2CA103 4) KIT,CAROTID ENDARTERECTOMY, Catalog Number:PVV2CA10T 5) KIT,CAROTID E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1166-2025·2025-02-19

    Novation XLE hip implant components recalled for missing barrier layer

    Exactech is recalling Novation XLE hip implant components due to absence of an Ethylene Vinyl Alcohol (EVOH) barrier layer. Patients with affected implants should contact their healthcare provider.

    Product
    Novation XLE Item Number / Product Description: 140-22-70 NV EHXL NTL LNR G00 22MM 140-28-50 NV EHXLNTRL LNR G0 28MM 140-28-51 NV EHXLNTRL LNR G1 28MM 140-28-52 NV EHXL NTRL LNR G228MM 140-32-51 NV EHXL NTRL LNR G132MM 140-32-52 NV EHXL NTRL LNR G232MM 140-32-53 NV EHXL N
    Category
    Medical Device
    Distribution
    22 states
  • HighFDA (Devices)·Z-1126-2025·2025-02-19

    Cardinal Health Surgical Kits Recalled for Potential Endotoxin Contamination

    Cardinal Health is recalling Presource surgical kits due to potential endotoxin contamination in non-sterile surgical strips and patties. Approximately 973,785 units were distributed to the US, Canada, and Saudi Arabia.

    Product
    Cardinal Health Presource Kits: 1) KIT,DIEP FLAP , Catalog Number:PB23DFCM3; 2) KIT,DIEP FLAP , Catalog Number:PB23DFCM4; 3) KIT,DIEP FLAP , Catalog Number:PB23DFCM5; 4) KIT,DIEP FLAP , Catalog Number:PB23DFCM6; 5)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1139-2025·2025-02-19

    Stryker Precision Thin surgical blade attachments recalled for specification defect

    Stryker is recalling Precision Thin surgical blade attachments that may be out of specification and fail to fit securely into compatible handpieces. The defect affects 238 units distributed worldwide, with no reported injuries.

    Product
    stryker Precision Thin, Catalog Number REF 2296-003-155; Micro Oscillating and Sagittal Blades
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1164-2025·2025-02-19

    Diagnostic HPV Verification Panel Recalled Due to Quality Control Failures

    Microbiologics Inc is recalling HPV verification test panels (REF 8235) due to quality control failures that allowed defective units to be released. The panels may produce invalid test results or fail to detect HPV.

    Product
    Microbiologics Multi-Strain Human Papillomavirus (HPV) Verification Panel (Inactivated Pellet), REF 8235; in-vitro diagnostic test
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1132-2025·2025-02-19

    Cardinal Health Presource Surgical Kits Recalled for Potential Endotoxin Contamination

    Cardinal Health is recalling approximately 973,785 Presource Kits due to potential endotoxin contamination in non-sterile surgical strips and patties. The kits were distributed to healthcare facilities worldwide.

    Product
    Cardinal Health Presource Kits: 1) KIT,NASAL SEPTOPLASTY,FAIRVIEW, Catalog Number:PE29NSFG4; 2) KIT,NASAL SEPTOPLASTY,FAIRVIEW, Catalog Number:PE29NSFG5 3) KIT,NASAL SEPTOPLASTY,FAIRVIEW, Catalog Number:PE29NSFG6 4) KIT,NASAL SEPTOPLASTY,FAIRVIEW, Catalog Number:PE29NSFG7 5) KIT,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1165-2025·2025-02-19

    Exactech AcuMatch XLE Hip Implants Recalled Due to Missing Protective Barrier Layer

    Exactech recalled AcuMatch XLE hip implants due to the absence of the Ethylene Vinyl Alcohol (EVOH) barrier layer. Approximately 42 units were distributed in the U.S. and internationally.

    Product
    AcuMatch XLE Item Number / Product Description: 140-28-27 AM EHXL 0¿ LNR G 28MM 140-32-27 AM EHXL 0¿ LNR G 32MM 140-32-28 AM EHXL 0¿ LNR H 32MM 140-28-29 AM EHXL 0¿ LNR J 28MM 140-32-29 AM EHXL 0¿ LNR J 32MM 140-36-29 AM EHXL 0¿ LNR J 36MM 140-32-30 AM EHXL 0¿ LNR K 32MM
    Category
    Medical Device
    Distribution
    22 states
  • HighFDA (Devices)·Z-1163-2025·2025-02-19

    HPV Diagnostic Control Panel Recall Due to Quality Control Failures

    Microbiologics is recalling a lot of HPV diagnostic control materials due to inadequate quality control during release. The control's HPV 16 L1 concentration is too low, potentially causing test failures and invalid results in clinical laboratories.

    Product
    Microbiologics Multi-Strain Human Papillomavirus (HPV) Control Panel (Inactivated Pellet), REF 8234; in-vitro diagnostic test
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.