  • HighFDA (Food)·F-1271-2024·2024-06-05

    Mother's Day Heart Box Recalled for Undeclared Coconut Allergen

    Maribel's Sweets, Inc. is recalling its 7.7-piece Mother's Day heart box due to undeclared coconut. The product may pose a risk to consumers with coconut allergies. Approximately 4,011 boxes were distributed nationwide and through online retailers.

    Product
    7. 7pc Mother s Day heart box
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1909-2024·2024-06-05

    Synchro Guide Wires Recalled for Inadequate Endotoxin Testing

    Stryker Neurovascular is recalling 2,859 Synchro guide wires in multiple configurations due to inadequate endotoxin testing during manufacturing. The devices may exceed acceptable endotoxin limits, increasing the risk of fever, shock, and aseptic meningitis.

    Product
    Synchro .014"guide wire, 35 cm tip, Catalog: M00313010 Synchro .014 guide wire, 300 cm length, Catalog: M00313310 SYNCHRO .010 WIRE SOFT STRAIGHT 200cm, Catalog: M00316310 SYNCHRO .010 WIRE SOFT STRAIGHT 300cm, Catalog: M00316330
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0531-2024·2024-06-05

    EYLEA injectable eye medication recalled due to sterility and syringe breakage

    Regeneron is recalling 405,725 prefilled syringes of EYLEA (aflibercept) eye injection due to lack of assurance of sterility and complaints of syringe breakage. This FDA Class II recall affects multiple lots distributed nationwide.

    Product
    EYLEA — EYLEA (AFLIBERCEPT)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1902-2024·2024-06-05

    Trevo XP ProVue neurovascular retriever devices recalled for inadequate endotoxin testing

    Stryker Neurovascular's Trevo XP ProVue Retriever devices did not undergo adequate endotoxin testing and may exceed safe limits, potentially causing fever, shock, and aseptic meningitis.

    Product
    Trevo XP ProVue Retriever 4 x 20, Catalog: 90182 Trevo XP ProVue Retriever 3 x 20, Catalog: 90183 Trevo XP ProVue Retriever 4 x 30, Catalog: 90185 Trevo XP ProVue Retriever 6 x 25, Catalog: 90186 Kits: TREVO XP 3X20+PRO14 2-PACK, Catalog: 80051 TREVO XP 4X20+PRO18…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0516-2024·2024-06-05

    Moxifloxacin Intraocular Injection Recalled for Sterility Assurance

    Imprimis NJOF, LLC is recalling specific lots of Moxifloxacin intraocular injections nationwide due to lack of assurance of sterility.

    Product
    Moxifloxacin 4 mg/0.8 mL Preservative-Free 0.8mL Single-Use vials for Intraocular Injection, Rx only, Imprimis NJOF, LLC. 1705 Route 46 West, unit 6B, Ledgewood, NJ 07852, NDC 71384-511-08
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1916-2024·2024-06-05

    Surgical screwdrivers recalled for failure to engage with implant screws

    Synthes surgical screwdrivers are being recalled because they lack a required relief cut and will not engage properly with 1.3mm and 1.5mm implant screws, potentially delaying surgery. The defect affects 261 units distributed in the US and Canada.

    Product
    STARDRIVE SCRWDRVR SHFT/T4 50MM/SELF-RETAINING/HXC-Intended for tightening, loosening, or removing of screw implants during orthopaedic surgery. Part Number: 03.130.010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1891-2024·2024-06-05

    Tri-Staple 2.0 surgical stapler cartridge damage may cause incomplete stapling

    Covidien is recalling 1681 units of Tri-Staple 2.0 surgical staples due to potential cartridge damage that may result in poor staple formation and incomplete staple lines during surgery.

    Product
    Tri-Staple 2.0 Black Reinforced Intelligent Reload- Applications in abdominal, gynecologic, pediatric and thoracic surgery for resection, transection of tissue and creation of anastomosis Model: SIGTRSB60AXT
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0512-2024·2024-06-05

    Epinephrine-Lidocaine Intraocular Injection Vials Recalled for Sterility Assurance

    Imprimis NJOF, LLC is recalling 14,180 vials of Epinephrine-Lidocaine intraocular injection due to lack of assurance of sterility. These vials were distributed nationwide within the United States.

    Product
    Epinephrine-Lidocaine HCl 0.25 mg/mL and 7.5 mg/mL Preservative-Free 1mL Single-Use vials for Intraocular Injection, Imprimis NJOF, LLC. 1705 Route 46 West, unit 6B, Ledgewood, NJ 07852, NDC 71384-640-01
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0510-2024·2024-06-05

    Zoledronic Acid Injection Recalled for Sterility Defect

    Dr. Reddy's Laboratories recalls Zoledronic Acid Injection 5mg/100mL due to lack of sterility assurance and leaking vials. Lot #G3000010 with 13,880 vials was distributed nationwide.

    Product
    ZOLEDRONIC ACID — ZOLEDRONIC ACID (ZOLEDRONIC ACID)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighNHTSA·24V403000·2024-06-05

    Timpte Recalls 2024-2025 Deck Trailers Due to Ramp Bolt Defect

    Timpte is recalling 2024-2025 1420 and 1424 deck trailers because retaining rod bolts may fall off, leaving the folding ramp unsecured and increasing injury risk.

    Product
    TIMPTE — TIMPTE TIMPTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V404000·2024-06-05

    2023 Fisker Ocean Software Defect Causes Loss of Drive Power

    Fisker is recalling all 2023 Ocean vehicles. A software defect in the MCU/VCU can cause unexpected loss of drive power, increasing crash risk.

    Product
    FISKER — FISKER OCEAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1890-2024·2024-06-05

    Vercise Genus Deep Brain Stimulation Device May Reset During Charging

    Boston Scientific is recalling Vercise Genus Deep Brain Stimulation devices that may reset during system checks while charging. The reset causes temporary loss of stimulation and may lead to symptom worsening.

    Product
    Vercise Genus Deep Brain Stimulation (DBS) Implantable Pulse Generator IPG: R16 IPG KIT, REF: M365DB12160, and R32 IPG KIT, REF: M365DB12320
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0520-2024·2024-06-05

    Pain Wizard Topical Pain Relief Recalled for Out-of-Specification Active Ingredient

    ARG Laboratories recalls Pain Wizard topical pain relief nationwide due to out-of-specification active ingredient and violative-grade propylene glycol used in manufacturing. No illnesses reported.

    Product
    Pain Wizard, Natural Relief for Muscular & Arthritic Pain, (Camphor 3%, Menthol 3%), Enriched with Capsaicin, Camphor, Menthol & MSM, Bottle with pump, NET WT 16 fluid oz / 473.17 ml, Made in USA, www.painwizard.com Pain Wizard LLC.PO Box 1099, Johnstown, CO 80534, UPC 8 63865…
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1899-2024·2024-06-05

    EsophaCap esophageal diagnostic sponge recalled for detachment risk

    Lucid Diagnostics recalls EsophaCap esophageal diagnostic sponges due to risk of sponge detachment from string during device removal. No injuries have been reported.

    Product
    Brand Name: EsophaCap Product Name: EsophaCap (20mm diameter, 20 pores/inch) Model/Catalog Number: EC20T20VI Software Version: N/A Product Description: EsophaCap is pouched as individual units. 10 units go into a shelf-box. Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1924-2024·2024-06-05

    Alcon ClearCut S and A-OK ophthalmic surgical knives recalled for sharpness defects

    Alcon is recalling about 19,867 ClearCut S and A-OK ophthalmic surgical knives worldwide due to an increase in complaints about blade sharpness.

    Product
    ClearCut S Safety Sideport Knife 1.0mm Dual Bevel Model/Catalog Number: 8065771540 Software Version: N/A Product Description: Ophthalmic Knife Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1911-2024·2024-06-05

    Mako Surgical Robot Software Error Causes Treatment Delay in Orthopedic Surgery

    Stryker Orthopaedics is recalling Mako surgical robot software due to an error that occurs when switching between surgical applications without restarting the system, resulting in treatment delays.

    Product
    Total Knee Arthroplasty (TKA) 2, Total Knee Arthroplasty (TKA) 1, Partial Knee Arthroplasty (PKA) 3, Total Hip Arthroplasty (THA) 4.0, 4.1 on Mako 3.0, 3.1. Software: TKA 2.0 + TKA 1.0.1 + THA 4.1 + PKA 3.0.2 + MGO 1.2.2 Application Part Number: 700001590414
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0527-2024·2024-06-05

    Golden Tiger Pain Relieving Cream Recalled for Out-of-Specification Propylene Glycol

    ARG Laboratories is recalling Golden Tiger Natural Pain Relieving Cream nationwide due to use of a violative grade of propylene glycol during manufacturing that renders the active ingredient out of specification.

    Product
    NATURAL PAIN RELIEVING CREAM, GOLDEN TIGER, (Camphor 3%, Menthol 3%)Enriched with Capsaicin, Aloe Vera, Willow Bark & MSM, Tube 4 oz (113.39 g), Mfr. for Golden Tiger USA Albuq, NM, UPC 1 82294 00002 4
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1915-2024·2024-06-05

    Mako robotic surgery system software error causes treatment delays

    Stryker Mako robotic surgery software exhibits increased Error #3 when switching between surgical applications without system restart, resulting in treatment delays. No patient injuries reported.

    Product
    Total Knee Arthroplasty (TKA) 2, Total Knee Arthroplasty (TKA) 1, Partial Knee Arthroplasty (PKA) 3, Total Hip Arthroplasty (THA) 4.0, 4.1 on Mako 3.0, 3.1 Software: TKA 2.0.es.1 + PKA 3.0.2.es.1 + THA 4.0. Application Part Number: 700002190743-05
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0523-2024·2024-06-05

    Aloe Gator SPF 40+ Sunscreen Recalled for Out-of-Specification Active Ingredients

    ARG Laboratories is recalling 4,013 units of Aloe Gator SPF 40+ sunscreen (Lot 04023C1) distributed nationwide because the active ingredient does not meet specifications.

    Product
    ALOE GATOR, (Octocrylene 8%, Octyl Methoxycinnamate 6%, Benzophone 3 6%, Octyl Salicylate 5%), Original Formula, SPF 40+, Broad Spectrum Protective Gel, Sport Performance, NET WT 1 OZ (28 g), Manufactured for AGS Brands.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1910-2024·2024-06-05

    Stryker Mako Surgical Robot Software Error Causes Treatment Delays

    Stryker's Mako surgical robots may experience software errors causing treatment delays when switching between surgical modes without proper system restart. This affects 334 units globally.

    Product
    Total Knee Arthroplasty (TKA) 2, Total Knee Arthroplasty (TKA) 1, Partial Knee Arthroplasty (PKA) 3, Total Hip Arthroplasty (THA) 4.0, 4.1 on Mako 3.0, 3.1. Software: TKA 2.0 + TKA 1.0.1 + THA 4.0.0.1 + PKA 3.0.2 Application Part Number: 700001590415
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0524-2024·2024-06-05

    Pain Wizard topical pain relief recalled for out-of-specification manufacturing

    ARG Laboratories recalls Pain Wizard pain relief cream nationwide due to manufacturing defect involving propylene glycol that did not meet specifications.

    Product
    Pain Wizard, Natural Relief for Muscular & Arthritic Pain, (Camphor 3%, Menthol 3%), Enriched with Capsaicin, Camphor, Menthol & MSM, Tube, NET WT 8 oz (226.79g), Made in the USA, painwizard.com PO Box 1099, Johnstown, CO 80534, UPC 8 63865 00011 6
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0528-2024·2024-06-05

    FDA recalls Pain Wizard topical pain relief for ingredient specification issues

    ARG Laboratories recalled Pain Wizard topical pain relief roll-on due to active ingredient out of specification and violative-grade propylene glycol used in manufacturing.

    Product
    Pain Wizard, Natural Relief for Muscular & Arthritic Pain, (Camphor 3%, Menthol 3%), Enriched with Capsaicin, Camphor, Menthol & MSM, Roll-On 3 fl oz (88.7ml), painwizard.com Made in the USA, PO Box 1099, Johnstown, CO 80534, UPC 8 63865 00010 9
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V400000·2024-06-04

    2024 Kia EV9 recalled for inadequate crash protection headliner

    Kia is recalling certain 2024 EV9 vehicles because the headliner may not adequately protect passengers from impact in a crash. The defect increases injury risk during accidents.

    Product
    KIA — KIA EV9
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V399000·2024-06-04

    Mack Recalls 2024 MD Electric Trucks for Battery Software Defect

    Mack Trucks is recalling 2024 MD Electric trucks because a battery software defect may cause sudden loss of steering and drive power, increasing crash risk.

    Product
    MACK — MACK MD (ELECTRIC)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V396000·2024-06-04

    Volvo Recalls 2025 Trucks Due to Drag Link Steering Failure Risk

    Volvo Trucks North America is recalling 2025 VN, VNRe, and VHD trucks because a defective drag link can cause sudden loss of steering control.

    Product
    VOLVO — VOLVO VNRE (ELECTRIC), VN, VHD
    Category
    Vehicle
    Distribution