Most US product recalls have nationwide distribution — the manufacturer ships into every state and the recall sweeps the same way. We include those in this listing because they affect Arkansas consumers even though the source notice doesn’t name the state. State-specific recalls are usually for products with regional distribution (a regional dairy, a local store brand) or where the agency was able to narrow the affected shipments to specific destinations.

If you’re checking whether a recall affects your purchase, the recall detail page lists the exact production lot codes, UPCs, and best-by dates. Match those against your package — distribution scope is a starting filter, not the final answer.

11026–11050 of 20199

  • HighFDA (Devices)·Z-0398-2024·2023-11-29

    Robotic patient positioning system may move unexpectedly after interruption

    The ORION System robotic arm used in radiation therapy may suddenly accelerate or move unexpectedly when motion resumes after an interruption, creating a risk of collision with stationary equipment.

    Product
    ORION System with software OSS v6.0 and OSS v7.0- An electro-mechanical robotic arm for patient positioning in Radiation Therapy, Radiology, or Radiology image-guided treatment environment. Part Number: 1SOPT00003
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0325-2024·2023-11-29

    IRON assay kits recalled for inaccurate diagnostic results

    Sentinel CH SpA is recalling IRON assay kits (Reference Numbers 6K95-41 and 6K95-30) that may produce falsely elevated results. Affected lots could cause inaccurate iron measurements and delays in patient test reporting.

    Product
    IRON assay, Reference Numbers 6K95-41 and 6K95-30
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0352-2024·2023-11-29

    Roche Tina-quant D-Dimer Test System Recalled for Inaccurate Results

    Roche is recalling Tina-quant D-Dimer Test System kits because they produce elevated results when used with lithium-heparin plasma samples, potentially affecting diagnostic accuracy.

    Product
    Tina-quant D-Dimer Test System, Fibrinogen/Fibrin Degradation Products Assay, Material Numbers 03001245322 - (cobas c 311, 501 and 502; INTEGRA 400 plus), 08105618190 - (cobas c 303 and 503)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0384-2024·2023-11-29

    Compress Device Short Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (22 MM) used in orthopedic surgery because they may contain metal burrs in the transverse holes that could prevent drill or pin passage and extend surgical procedures.

    Product
    Compress Device Short Anchor Plug, 22 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178564
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0326-2024·2023-11-29

    Alinity c Iron Reagent Recalled for Falsely Elevated Test Results

    The FDA is recalling Alinity c Iron Reagent lots due to inaccurate results. The reagent produces falsely elevated patient iron values and may prevent proper quality control verification.

    Product
    Alinity c Iron Reagent, Reference Number 08P3920
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0399-2024·2023-11-29

    ORION Robotic Arm Recalled for Sudden Acceleration and Collision Risk

    The FDA recalls ORION robotic positioning arms used in radiation and radiology due to sudden acceleration or unintended movement that could cause patient collision with treatment room equipment. No injuries reported.

    Product
    ORION System with software OSS v6.0 and OSS v7.0- An electro-mechanical robotic arm for patient positioning in Radiation Therapy, Radiology, or Radiology image-guided treatment environment. Part Number: 1SOPT00009
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0333-2024·2023-11-29

    Gastroscope Devices Recalled for Inadequate Channel Drying Process

    Aizu Olympus recalls 680 gastroscope-EUS devices due to unvalidated channel drying. Water remaining in the channels poses contamination and infection risks.

    Product
    Gastroscope-endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) and for endoscopic surgery within the upper digestive tract. Model Numbers: GF-UC140P-AL5, GF-UCT180, GF-UE160-AL5.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0113-2024·2023-11-29

    Buspirone Hydrochloride Tablets Recalled Due To Amlodipine Contamination Risk

    FDA recalls Buspirone Hydrochloride 10 mg tablets due to potential contamination with foreign Amlodipine Besylate tablets. The recall affects 1,344 blister cards distributed nationwide.

    Product
    BUSPIRONE HYDROCHLORIDE — BUSPIRONE HYDROCHLORIDE (BUSPIRONE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0344-2024·2023-11-29

    Transnasal Esophagovideoscope Recalled Due to Unvalidated Drying Process

    Aizu Olympus is recalling the Transnasal Esophagovideoscope (Model PEF-V) because the channel air drying process was not validated, resulting in some units with wet channels that could cause infection.

    Product
    Transnasal esophagovideoscope-For endoscopy and endoscopic surgery within the esophagus and stomach. Model Number: PEF-V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0337-2024·2023-11-29

    Hysterofiberscope Model HYF-XP Channel Drying Process Flaw Poses Infection Risk

    Aizu Olympus is recalling HYF-XP hysterofiberscopes because the channel air drying process was not validated. Some repaired units have wet channels that could harbor contamination and pose infection risk.

    Product
    Hysterofiberscope-For endoscopic diagnosis within the uterus. Model Number: HYF-XP.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0386-2024·2023-11-29

    Surgical implant anchor plugs may contain metal burrs affecting insertion

    Biomet's Compress Device Short Anchor Plugs may contain metal burrs in the transverse holes, which can prevent proper insertion of surgical tools and extend surgery time. The affected devices are distributed nationwide and internationally.

    Product
    Compress Device Short Anchor Plug, 24 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178566
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0377-2024·2023-11-29

    Biomet Anchor Plugs Recalled: Metal Burrs Prevent Proper Assembly

    Biomet's Compress Device Segmental Anchor Plugs are being recalled due to metal burrs in assembly holes. The defect prevents drill pins from passing through, potentially extending surgical time during implantation procedures.

    Product
    Compress Device Segmental Anchor Plug, 24 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178414
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0336-2024·2023-11-29

    Hysterovideoscope Models Recalled Due to Improper Channel Drying Risk

    Aizu Olympus is recalling Hysterovideoscope Model HYF-V units (27 devices) because the channel air drying process was not validated. Water remaining in device channels could pose an infection risk.

    Product
    Hysterovideoscope-For endoscopic diagnosis within the uterus Model Number: HYF-V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0362-2024·2023-11-29

    BreathTech Manual Resuscitators Recalled for Integrated Manometer Leak

    SunMed Holdings is recalling BreathTech manual resuscitators because the integrated manometer can leak, allowing patients to rebreathe exhaled CO2 during emergency airway management.

    Product
    Ventlab, LLC BreathTech manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. BreathTech Adult Resuscitator REF #s: BT5107F & BT5104P; 2. BreathTech Child Resuscitator REF #s: BT3030, BT3034, & BT3025; 3. BreathTech Infant Res
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0391-2024·2023-11-29

    Philips Achieva 1.5T MRI Systems Recalled for Gradient Coil Fire Risk

    Philips is recalling Achieva 1.5T MRI systems because the gradient coil component could fail and produce smoke or fire. The recall affects 2 units distributed worldwide.

    Product
    Achieva 1.5T Initial System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0338-2024·2023-11-29

    Tracheal Fiberscope Airway Management Devices Recalled for Inadequate Channel Drying

    Aizu Olympus is recalling 65 tracheal fiberscope units worldwide due to an unvalidated air drying process. Moisture remaining in device channels after repair could allow contamination and pose an infection risk.

    Product
    Tracheal fiberscope-airway management, which includes observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Numbers: LF-DP, LF-GP, LF-TP.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0363-2024·2023-11-29

    Horizon manual resuscitators recalled for CO2 rebreathing hazard

    SunMed Holdings is recalling Ventlab Horizon manual resuscitators due to a backwards leak in the integrated manometer that allows carbon dioxide rebreathing. The affected devices were manufactured from September 2018 to the present and distributed nationwide.

    Product
    Ventlab, LLC Horizon manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. Horizon Adult Resuscitator REF #s: 9122HZ, HZI9000, HZI9108, 9106HZ, 9110HZ, 9120HZ, 9111HZ, 9100HZ, 9105HZ, 9108HZ, 9006HZ, 9002HZ; 2. Horizon Infant Resu
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0346-2024·2023-11-29

    Olympus endoscopes recalled for potential water contamination in channels

    Aizu Olympus Co., Ltd. is recalling duodenovideoscope models due to an unvalidated channel air drying process. Water remaining in the channels after repair poses a potential contamination risk that could lead to infection.

    Product
    Duodenovideoscope-EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery Model Numbers: TJF-145, TJF-150, TJF-Q180V, TJF-Q190V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0374-2024·2023-11-29

    Biomet Compress Anchor Plugs Recalled for Metal Burrs in Transverse Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs (18 MM) due to metal burrs in transverse holes that may prevent proper drill or pin placement, potentially extending surgery time.

    Product
    Compress Device Segmental Anchor Plug, 18 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178408
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0389-2024·2023-11-29

    Philips Achieva 1.5T MRI systems recalled for potential gradient coil fire risk

    Philips is recalling Achieva 1.5T MRI systems due to potential gradient coil failure that could produce smoke and/or fire. Approximately 520 units have been distributed nationwide and internationally.

    Product
    Achieva 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0373-2024·2023-11-29

    Biomet Compress Device Segmental Anchor Plugs Recalled for Metal Burrs

    Biomet has recalled certain Compress Device Segmental Anchor Plugs (16 MM) due to metal burrs in the transverse holes. These burrs may prevent the drill or pins from passing through, potentially extending surgical time.

    Product
    Compress Device Segmental Anchor Plug, 16 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178406
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0341-2024·2023-11-29

    Colonoscopes recalled over unvalidated channel drying process

    Aizu Olympus colonoscopes are being recalled because the air drying process for the instrument channel was not properly validated. Some units returned after repair had moisture in the channel, creating a risk of contamination and infection.

    Product
    Colonoscope-indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, colon, and ileocecal valve). Model Numbers: PCF-H180AI, PCF-H180AL, PCF-H190DI, PCF-H190DL, PCF-H190I, PCF-H190L, PCF-H190TI, PCF-H190TL, PCF-HQ190I, PCF-HQ190L, PCF-PH190I
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0353-2024·2023-11-29

    BioFire FilmArray TORCH power switch may fail from electrical arcing

    BioFire FilmArray TORCH diagnostic devices have a power switch that may degrade from internal arcing and carbon buildup, potentially causing electrical short, device overheating, or failure to power on.

    Product
    FilmArray TORCH REF HTFA-ASY-0104. HTFA-ASY-0104 is the BIOFIRE TORCH Base which includes barcode scanner, touch screen computer and USB ports. The BioFire FilmArray Torch (BioFire Torch) is an automated in vitro diagnostic (IVD) device intended for use with FDA-cleared or ap
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0368-2024·2023-11-29

    Curaplex Manual Resuscitators Recalled for Potential CO2 Rebreathing Risk

    SunMed Holdings is recalling Curaplex manual resuscitators with integrated manometers due to a backwards leak in the patient valve that allows carbon dioxide rebreathing. All units manufactured from September 2018 to present and distributed nationwide are affected.

    Product
    Curaplex manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. Curaplex Adult Premium BVM with Bag Reservoir, Manometer, Filter, Peep Valve & Mask, REF # 2442-BVMPAD; 2. Curaplex Child Premium BVM with Bag Reservoir, Manometer, 2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0371-2024·2023-11-29

    Compress Device Anchor Plugs recalled due to metal burrs

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs in transverse holes that may prevent drill or pins from passing through, potentially extending surgical time.

    Product
    Compress Device Segmental Anchor Plug, 12 MM -For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178402
    Category
    Medical Device
    Distribution