The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

8876–8900 of 40056

  • HighFDA (Devices)·Z-0136-2024·2023-11-15

    IV Fitting Components Recalled Due to Manufacturing Defect and Leakage Risk

    B. Braun Medical is recalling 175,000 units of bulk largebore male LL fittings due to a manufacturing defect that may cause leakage, potentially increasing bloodstream infection risk.

    Product
    BULK LARGEBORE MALE LL FITTING, Article No. M4341750SN. IV administration component.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0218-2024·2023-11-15

    CardioMEMS Patient Electronic System power connector damage risk

    St. Jude Medical is recalling CardioMEMS Patient Electronic System (Model CM1100) because the power connector plug may become damaged and frayed if bent beyond 90 degrees. This could cause device malfunction or electrical hazard.

    Product
    CardioMEMS Patient Electronic System (PES), Model Number CM1100. Used for wirelessly measuring and monitoring pulmonary artery pressure and heart rate.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0224-2024·2023-11-15

    Philips surgical imaging systems missing warning label and safety spacer

    Philips has recalled certain surgical C-arm imaging systems delivered to Puerto Rico because they lack required warning labels and are missing a critical Source-to-Skin Distance Spacer component.

    Product
    BV Endura, BV Pulsera Philips Image Guided Therapy-Systems (IGTS)Mobile Surgery C-arm systems.
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0226-2024·2023-11-15

    Surgical C-arm systems recalled for missing warning label and spacer

    Philips is recalling Zenition 50 & 70 surgical C-arm systems distributed to Puerto Rico, Guam, and the Virgin Islands due to missing warning labels and safety spacers. These missing components may compromise radiation safety during surgical use.

    Product
    Zenition 50 & 70 Mobile Surgery C-arm
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-0268-2024·2023-11-15

    ARC Teeth Whitening Pen Recalled Due to Improper Storage

    Family Dollar recalls 329,044 units of ARC Teeth Whitening Pen sold between June and October 2023 across 22 states due to improper storage outside temperature requirements.

    Product
    ARC TEETH WHITENING PEN 0.06 FL OZ, SKU 997950
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0248-2024·2023-11-15

    Disposable Bipolar Forceps Shelf Life Labeling Error Stryker

    Stryker recalls disposable Spetzler-Malis bipolar forceps due to incorrect shelf life labeling. The label states 54 months but the actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 20CM IM DISP BAYONET 0.5MM TIP, Catalog Number 6770-200-005
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0263-2024·2023-11-15

    Fixodent Denture Cream Recalled Due to Improper Storage Conditions

    Family Dollar is recalling 329,044 units of Fixodent denture cream products due to improper storage outside labeled temperature requirements. No illnesses or injuries have been reported.

    Product
    FIXODENT ORG CREAM 2.4OZ, SKU 906018 FIXODENT ADH CREAM WITH SCOPE 2OZ, SKU 906402 FIXODENT ORG CREAM TRAVEL .75OZ, SKU 901239
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0285-2024·2023-11-15

    Dental Prophylaxis Cups Recalled Due to Wrong Product in Packaging

    One lot of Contra Gray Soft Turbo Plus dental prophylaxis cups may contain Contra Petite Web LF Soft Purple Cup dental angles instead. The recalled product was distributed in Indiana, Tennessee, and Missouri.

    Product
    CONTRA GRAY (soft) TURBO PLUS CUPS, REF 153112. Dental Prophylaxis Angles
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-0262-2024·2023-11-15

    Family Dollar marijuana test strips recalled over improper storage

    Family Dollar recalled 329,044 at-home marijuana test strips (SKU 900752) due to improper storage outside labeled temperature requirements. Products were distributed across 22 states between June and October 2023.

    Product
    AT HOME MARIJUANA TEST STRIP, SKU 900752
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0242-2024·2023-11-15

    Disposable Surgical Forceps Recalled for Incorrect Expiration Date Labeling

    Stryker Corporation is recalling 2,321 units of Disposable Spetzler-Malis Bipolar forceps due to an error in the product label's expiration date. The label indicates a 54-month shelf life when the actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 23CM SM DISP BAYONET 0.5MM TIP, Catalog Number 6760-230-005
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0267-2024·2023-11-15

    Denture cleanser tablets recalled due to improper storage conditions

    Family Dollar recalls 329,044 units of GoodSense denture cleanser tablets that were stored outside their labeled temperature requirements. Products were sold between June and October 2023 at Family Dollar stores across 24 states.

    Product
    GOODSENSE DENTURE CLEANSER GRN TAB 40CT, SKU 906312 GOODSENSE DENTURE CLEAN OVRNT TAB 40CT, SKU 906023
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0269-2024·2023-11-15

    Contact Lens Solution Recalled for Improper Storage Temperature

    Family Dollar's MEDIC's CHOICE contact lens solution was distributed between June and October 2023 due to storage outside labeled temperature requirements. Approximately 329,044 units were affected across 22 states.

    Product
    MEDIC's CHOICE CONTACT LENS SOLUTION 12FLOZ, SKU 998935
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0253-2024·2023-11-15

    Surgical forceps recalled due to mislabeled shelf life

    Stryker Corporation is recalling Disposable Spetzler-Malis Bipolar forceps due to a labeling error showing an incorrect expiration date. The label states a 54-month shelf life when the actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 20CM SLM DISP BAYONET 1.0MM, Catalog Number 6780-200-010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0256-2024·2023-11-15

    Stryker surgical forceps recall due to incorrect expiration date labeling

    Stryker Corporation is recalling Spetzler-Malis Bipolar forceps due to incorrect shelf-life labeling. The devices are labeled with a 54-month shelf life but actually expire after 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 23CM SLM DISP BAYONET 1.0MM, Catalog Number 6780-230-010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0245-2024·2023-11-15

    Disposable surgical forceps recalled for incorrect expiration date labeling

    Stryker recalls disposable Spetzler-Malis Bipolar forceps due to expiration date labeling error. Labels show 54-month shelf life but actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 18CM IM DISP BAYONET 0.5MM TIP, Catalog Number 6770-180-005
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0250-2024·2023-11-15

    Disposable Bipolar Forceps Recalled for Incorrect Expiration Date Labeling

    Stryker Corporation is recalling 2,321 units of Disposable Spetzler-Malis Bipolar forceps due to incorrect expiration date labeling. The product label indicates a 54-month shelf life, but the actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 23CM IM DISP BAYONET 0.5MM TIP, Catalog Number 6770-230-005
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0266-2024·2023-11-15

    First Response 2 CT Recalled for Improper Temperature Storage

    Family Dollar recalled 329,044 First Response 2 CT units sold between June and October 2023 due to storage outside labeled temperature requirements. The recall affects 22 states.

    Product
    FIRST RESPONSE 2 CT, SKU 902343
    Category
    Medical Device
    Distribution
    23 states
  • ModerateFDA (Devices)·Z-0257-2024·2023-11-15

    Stryker Bipolar Forceps Recalled for Incorrect Expiration Date Label

    Stryker Corporation is recalling 2,321 units of Disposable Spetzler-Malis Bipolar forceps due to incorrect expiration date labeling. The label states a 54-month shelf life when the actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 23CM SLM DISP BAYONET 1.5MM, Catalog Number 6780-230-015
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0270-2024·2023-11-15

    Oral B Mouth Sore Rinse Recall Due to Improper Storage Conditions

    Family Dollar is recalling approximately 329,044 units of Oral B Mouth Sore Rinse 237ML because the product was stored outside of labeled temperature requirements. No illnesses or injuries have been reported.

    Product
    ORAL B MOUTH SORE RINSE 237ML, SKU 999087
    Category
    Medical Device
    Distribution
    23 states
  • SevereFDA (Devices)·Z-0144-2024·2023-11-08

    Stolen McGRATH MAC Video Laryngoscopes Recalled for Failed Quality Tests

    Covidien recalls 5,709 stolen McGRATH MAC video laryngoscopes that failed quality tests. These defective devices risk failed intubation and may compromise airway management.

    Product
    Stolen McGRATH MAC Video Laryngoscopes, REF: 301-000-000
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0170-2024·2023-11-08

    Senhance Robotic Surgical System uncontrolled arm motion malfunction

    Asensus Surgical recalls 21 units of Senhance Surgical System due to uncontrolled laparoscope arm motion after surgeons disengage remote control. The malfunction has occurred and may recur on affected devices.

    Product
    Senhance Surgical System, which includes: Manipulator Arm, ISU Configuration ( Catalog Number X9007708), Intelligent Surgical Unit (Catalog Number X9007696), and Cockpit, ISU Configuration (Catalog Number X9007707), Software (SW) version 2.7.4; robotic surgical system
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-0200-2024·2023-11-08

    RX Imola Clinical Chemistry Analyzer rerun feature may report results incorrectly

    RX Imola-IVD Clinical Chemistry Analyzers may report test results incorrectly when handling out-of-range samples due to improper parameter rerun settings. 35 units nationwide are affected.

    Product
    RX Imola-IVD Clinical Chemistry Analyzer Catalog Number: RX4900. RX4900R (refurbished)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0208-2024·2023-11-08

    POC Analyzer Risk of Erroneous Creatinine Results During Cartridge Startup

    Nova Biomedical's Stat Profile Prime Plus POC analyzer may report inaccurate creatinine results during the first 2-4 hours after sensor cartridge installation. Standard quality control checks may not detect these errors.

    Product
    Nova Stat Profile Prime Plus POC Analyzer (CE)-Intended to measure certain gases in blood, serum, plasma or pH of blood, serum, and plasma. (1) PN 63368 Stat Profile Prime Plus POC Analyzer (2) PN 63369 Stat Profile Prime Plus POC Analyzer, Remanufactured P/N: 57400, 633
    Category
    Medical Device
    Distribution
    Distributed nationwide