The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3501–3525 of 39948

  • HighFDA (Devices)·Z-2215-2025·2025-08-06

    SmartPath to dStream 3.0T gradient coils may act as heat source

    SmartPath to dStream for 3.0T systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 15 units affected.

    Product
    SmartPath to dStream for 3.0T Model Number (REF): 782145;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2211-2025·2025-08-06

    Philips Ingenia Elition X gradient coils may act as heat source

    Ingenia Elition X MR systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 632 units are affected.

    Product
    Ingenia Elition X Model Numbers (REF): (1) 781358, (2) 782107, (3) 782119, (4) 782136, (5) 782151 (China ONLY);
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2223-2025·2025-08-06

    Blood agar plates may carry Listeria monocytogenes surface contamination

    Blood Agar with 5% Sheep Blood, product number R01202, is being recalled because the products may contain surface and subsurface contamination of Listeria monocytogenes. 1,552 units affected.

    Product
    Blood Agar,5% Sheep Blood 100/PK, Product Number R01202
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2222-2025·2025-08-06

    Osteotec silicone finger implants may contain foreign material

    Osteotec Silicone Finger Implants in sizes 3, 4 and 5 are being recalled because there is the potential that the silicone implant may contain foreign material. 15,573 units are affected.

    Product
    Brand Name: Osteotec Product Name: Osteotec Silicone Finger Implant Model/Catalog Number: OSTF-3 (Sz. 3), OSTF-4 (Sz. 4), OSTF-5 (Sz. 5) Software Version: N/A Product Description: The Osteotec Silicone Finger Implant is a one-piece, sterile, flexible silicone elastomer implan
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2198-2025·2025-08-06

    CoSense sampling sets may carry residual carbon monoxide from insufficient aeration

    Precision Sampling Sets for the CoSense End-Tidal Carbon Monoxide Monitor are being recalled because residual carbon monoxide may remain in the cannula filter, which may raise ETCOc scores. 2,160 units affected.

    Product
    Precision Sampling Set, REF: C20206 for use with the CoSense End-Tidal Carbon Monoxide Monitor
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2209-2025·2025-08-06

    Philips Ingenia Ambition X gradient coils may act as heat source

    Ingenia Ambition X MR systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 690 units are affected.

    Product
    Ingenia Ambition X Model Numbers (REF): (1) 781356, (2) 782109, (3) 782138;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2202-2025·2025-08-06

    Philips Evolution Upgrade 1.5T gradient coils may act as a heat source

    Evolution Upgrade 1.5T MR systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 93 units are affected.

    Product
    Evolution Upgrade 1.5T Model Numbers (REF): (1) 782116, (2) 782148;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2199-2025·2025-08-06

    SwabFlush prefilled syringes carry SwabCaps with a compromised seal

    SwabFlush Prefilled Syringes with ICU Medical SwabCaps are being recalled because a manufacturing issue affects the SwabCap seal, which may reduce disinfection of the luer access valve. 1,427,100 units affected.

    Product
    SwabFlush Prefilled Syringe with ICU Medical SwabCaps, 10mL Model no. EMZE010301
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2217-2025·2025-08-06

    SmartPath to Ingenia Elition X gradient coils may overheat

    SmartPath to Ingenia Elition X systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 33 units affected.

    Product
    SmartPath to Ingenia Elition X Model Numbers (REF): (1) 782118, (2) 782144;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2203-2025·2025-08-06

    Philips Evolution Upgrade 3.0T gradient coils may act as heat source

    Evolution Upgrade 3.0T MR systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 50 units are affected.

    Product
    Evolution Upgrade 3.0T Model Numbers (REF): (1) 782117, (2) 782143;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2210-2025·2025-08-06

    Philips Ingenia Elition S gradient coils may act as a heat source

    Ingenia Elition S MR systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 242 units are affected.

    Product
    Ingenia Elition S Model Numbers (REF): (1) 781357, (2) 782106, (3) 782137, (4) 782150 (China ONLY);
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2221-2025·2025-08-06

    Volcano Visions IVUS catheters can entangle with the guide wire

    Volcano Visions Digital IVUS Catheters are being recalled following reports of catheter and guide wire entanglement during radial-to-peripheral procedures, which may require surgical removal. 233,817 units affected.

    Product
    Volcano Visions Digital IVUS Catheter: PV.014P (Platinum), REF:85910P; PV.014P RX, REF: 014R; and PV.018, REF: 86700, 86700J used with Instructions for use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2233-2025·2025-08-06

    LVP blood administration sets have potential for external cassette leaks

    LVP Blood Products Administration Sets are being recalled because of the potential for external cassette leaks. 14,280 units are affected.

    Product
    LVP Blood Products Administration Set Dual-Inlet, Low-Sorbing, Y-Site, Mesh Filter (Qty 20). Product Code: SET-0014-20.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2214-2025·2025-08-06

    Philips MR 7700 gradient coils may act as a heat source

    MR 7700 systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 82 units are affected.

    Product
    MR 7700 Model Numbers (REF): (1) 782120, (2) 782153;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2206-2025·2025-08-06

    Philips Ingenia 3.0T gradient coils may act as a heat source

    Ingenia 3.0T MR systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 1,467 units are affected.

    Product
    Ingenia 3.0T Model Numbers (REF): (1) 781342, (2) 781377, (3) 782103;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2208-2025·2025-08-06

    Philips Ingenia Ambition S gradient coils may act as heat source

    Ingenia Ambition S MR systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 611 units are affected.

    Product
    Ingenia Ambition S Model Numbers (REF): (1) 781359, (2) 782108, (3) 782133 (China ONLY), (4) 782139;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2207-2025·2025-08-06

    Philips Ingenia 3.0T CX gradient coils may act as heat source

    Ingenia 3.0T CX MR systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 350 units are affected.

    Product
    Ingenia 3.0T CX Model Numbers (REF): (1) 781271, (2) 782105;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2174-2025·2025-08-06

    HeartSine samaritan public access defibrillators may not deliver shocks properly

    HeartSine SAM 350P, 360P and 450P public access defibrillators are being recalled because a component manufacturing issue means the device may not function properly to deliver shocks. 190,516 units affected.

    Product
    HeartSine SAM 350P, HeartSine SAM 360P, and HeartSine SAM 450P The HeartSine samaritan¿ PAD (Public Access Defibrillator)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2234-2025·2025-08-06

    LVP primary administration sets have potential for external cassette leaks

    LVP Primary Administration Sets, Single Outlet Low Sorbing, are being recalled because of the potential for external cassette leaks. 35,925 units are affected.

    Product
    LVP Primary Administration Set, Single Outlet Low Sorbing (Qty 25). Product Code: SET-0021-25.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2216-2025·2025-08-06

    SmartPath to dStream XR gradient coils may act as heat source

    SmartPath to dStream for XR and 3.0T systems are being recalled because component failures in the gradient coil may act as a heat source with the potential to produce smoke or fire. 294 units affected.

    Product
    SmartPath to dStream for XR and 3.0T Model Numbers (REF): (1) 781270, (2) 782113, (3) 782129;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2175-2025·2025-08-06

    Inseego dongle kit flash drives carry outdated patient monitor software

    Inseego USB8 4G Dongle Kits for the Tempus Pro Monitor are being recalled because the kit's USB flash drive contains outdated software that could revert the monitor and reintroduce a previous issue. 55 units affected.

    Product
    Inseego USB8 4G Dongle Kit, Part Number: 01-2298, which contains USB Flash Drive, Part Number: 43-2011. The kit is an accessory to the Tempus Pro Monitor, REF: 00-1007-R, 00-1024-R, 00-1026-R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2226-2025·2025-08-06

    Blood MacConkey biplates may carry Listeria monocytogenes surface contamination

    Blood/MacConkey Biplates, product number R02049, are being recalled because the products may contain surface and subsurface contamination of Listeria monocytogenes. 611 units are affected.

    Product
    Blood/MacConkey Biplate 100/PK, Product Number R02049
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2225-2025·2025-08-06

    Blood EMB Levine plates may carry Listeria monocytogenes contamination

    Blood/EMB Levine plates, product number R02041, are being recalled because the products may contain surface and subsurface contamination of Listeria monocytogenes. 750 units are affected.

    Product
    Blood/EMB, Levine 100/PK, Product Number R02041
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2188-2025·2025-08-06

    LIFEPEARL microspheres are smaller than specification, risking non-targeted embolization

    LIFEPEARL Drug Elutable Microspheres are being recalled because their actual average diameter is smaller than specification, which may lead to non-targeted embolization. 1,451 units affected.

    Product
    LIFEPEARL Drug Elutable Microspheres: 200 +/- 50 micrometers, REF: 8LP2S200; 400 +/- 50 micrometers, REF: 8LP2S400
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2232-2025·2025-08-06

    LVP dual-inlet administration sets have potential for external cassette leaks

    LVP Primary Administration Sets, Dual-Inlet, Low-Sorbing, Needle-Free Port, Y-Site, are being recalled because of the potential for external cassette leaks. 19,225 units are affected.

    Product
    LVP Primary Administration Set, Dual-Inlet, Low-Sorbing, Needle-Free Port, Y-Site (Qty 25). Product Code: SET-0013-25.
    Category
    Medical Device
    Distribution
    Distributed nationwide