The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

276–300 of 337

  • HighFDA (Devices)·Z-2262-2023·2023-08-09

    Bronchoscopy Instruments Recalled for Electromagnetic Sensor Tracking Malfunction

    Olympus Corporation is recalling Always-On Tip Tracked Instruments due to a malfunction in the electromagnetic sensor that impairs navigation functionality during bronchoscopic procedures. The malfunction could result in procedural delays.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive¿ instruments) Brush, 15mm L, 1.8mm OD Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic bronchoscopy are currently used for visualizing Model: INS-0352
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2267-2023·2023-08-09

    Olympus SPiN Drive Triple Needle Brush Recalled for Sensor Malfunction

    Olympus Corporation recalls the Always-On Tip Tracked Triple Needle Brush due to electromagnetic sensor tracking malfunction that impairs navigation functionality during endobronchial procedures, potentially causing procedural delays.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive instruments) Triple Needle Brush, 12mm L, 1.8mm OD-Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing Model:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2265-2023·2023-08-09

    Olympus SPiN Drive Histology Needle Recalled for Navigation Sensor Malfunction

    Olympus recalls SPiN Drive histology needles due to electromagnetic sensor tracking malfunction that impairs navigation functionality during endobronchial procedures, potentially causing procedural delays.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive instruments) 19ga ANSO Histology Needle, 12mm L, 1.8mm OD-Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2268-2023·2023-08-09

    SPiN Drive Needle Navigation Sensor Malfunction Triggers Procedural Delays

    Olympus SPiN Drive needles have an electromagnetic sensor tracking malfunction that impairs navigation during endobronchial clinical procedures. Affected devices may generate false coil break warnings and cause procedural delays.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive instruments) 22ga SPiN Flex Needle, 12mm L, 1.8mm OD-Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing Mode
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2263-2023·2023-08-09

    Olympus Forceps Model INS-0362 Navigation Sensor Malfunction During Procedures

    Always-On Tip Tracked Instruments forceps (Model INS-0362) may experience electromagnetic sensor tracking malfunction during endobronchial procedures, impairing navigation functionality and causing procedural delays.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive instruments) Forceps, 1.8 mm OD, Oval Cup-Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing Model: INS-0362
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2264-2023·2023-08-09

    Olympus SPiN Drive Forceps Recalled for EM Sensor Malfunction

    Olympus SPiN Drive Forceps are being recalled due to an electromagnetic sensor malfunction that disables navigation functionality during endobronchial procedures, potentially causing procedural delays. No injuries reported.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive instruments) Forceps, 1.8mm OD, Serrated Cup-Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing Model: INS-0
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2269-2023·2023-08-09

    SPiN Xtend Instruments Recalled for Electromagnetic Sensor Tracking Malfunction

    Olympus Corporation is recalling 144 units of SPiN Xtend 2.0mm OD instruments (Model INS-5450) due to electromagnetic sensor tracking malfunction that impairs navigation during endobronchial procedures and may cause procedural delays.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive instruments) SPiN Xtend 2.0mm OD, 21ga Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing Model: INS-5450
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2266-2023·2023-08-09

    Endobronchial Cytology Needles Recalled for Electromagnetic Sensor Malfunction

    Olympus is recalling endobronchial navigation needles because an electromagnetic sensor malfunction can disable navigation guidance during medical procedures, potentially causing procedural delays.

    Product
    Always-On Tip Tracked Instruments (SPiN Drive instruments) 21ga ANSO Cytology Needle, 12mm L, 1.8mm OD-Intended for use in clinical interventions and for anatomical structures where computed tomography and/or endoscopic brINS-0362onchoscopy are currently used for visualizing
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2016-2023·2023-07-26

    Olympus Bronchovideoscope Recalled for Endobronchial Combustion Risk

    Olympus is recalling 17,609 bronchovideoscope units nationwide due to complaints of endobronchial combustion during therapeutic laser procedures, which poses a fire and burn risk to patients.

    Product
    Olympus EVIS EXERA II BRONCHOVIDEOSCOPE BF TYPE, Model Numbers BF-P180, BF-Q180, BF-Q180-AC, BF-1T180, BF-1TQ180
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2015-2023·2023-07-26

    Olympus BRONCHOVIDEOSCOPE Model BF-Q170 Recalled Due to Combustion Risk

    Olympus BRONCHOVIDEOSCOPE Model BF-Q170 is recalled nationally due to complaints of endobronchial combustion during therapeutic laser procedures, classified as FDA Class I.

    Product
    Olympus BRONCHOVIDEOSCOPE, Model Numbers BF-Q170
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2013-2023·2023-07-26

    Olympus Bronchoscope Recall: Risk of Combustion During Laser Procedures

    Olympus is recalling 9 bronchoscopes (Models BF-P150 and BF-1T150) due to complaints of endobronchial combustion during therapeutic laser procedures. The defect could cause fire and serious burn injuries.

    Product
    Olympus BRONCHOVIDEOSCOPE BF Type, Model Numbers BF-P150, BF-1T150
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2014-2023·2023-07-26

    Olympus EVIS EXERA Bronchoscope Recalled for Combustion Risk During Laser Procedures

    The FDA recalls 284 Olympus EVIS EXERA bronchoscopes due to complaints of combustion during therapeutic laser procedures. Users should stop using affected models immediately.

    Product
    Olympus EVIS EXERA BRONCHOVIDEOSCOPE BF TYPE, Model Number BF-XT160
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2017-2023·2023-07-26

    Olympus EVIS EXERA III Bronchovideoscope Combustion Hazard Recall

    Olympus is recalling EVIS EXERA III Bronchovideoscopes nationwide due to complaints of endobronchial combustion during therapeutic laser procedures. This FDA Class I recall affects approximately 9,684 units.

    Product
    Olympus EVIS EXERA III BRONCHOVIDEOSCOPE BF TYPE, Model Numbers BF-H190, BF-Q190, BF-XT190, BF-1TH190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2012-2023·2023-07-26

    Olympus Bronchofiberscope BF Type recalled for combustion risk during laser procedures

    Olympus bronchoscopes (Models BF-PE2 and BF-TE2) are recalled due to reports of combustion inside the airway during laser-assisted medical procedures. This is an FDA Class I recall.

    Product
    Olympus BRONCHOFIBERSCOPE BF Type, Model Numbers BF-PE2, BF-TE2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1990-2023·2023-06-28

    Hemostatic Clip Device Recalled Due to Deployment Failures

    Olympus recalls QUICKCLIP PRO hemostatic clips nationwide due to reported malfunction during clinical procedures, where clips fail to open, close, or detach from tissue as intended.

    Product
    Single Use Repositionable Clip QUICKCLIP PRO 230CM 5/BX- Intended for hemostatic metal clip for the GI Tract Catalog Number: HX-202UR.B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1987-2023·2023-06-28

    Olympus QUICKCLIP PRO hemostatic clips recalled for deployment failures

    Olympus is recalling 340 QUICKCLIP PRO hemostatic clips used in gastrointestinal endoscopy due to reports of deployment failures during procedures, including clips that fail to open, close, or detach properly.

    Product
    Single Use Repositionable Clip QUICKCLIP PRO 165 CM 10/BX- Intended for hemostatic metal clip for the GI Tract Catalog Number: HX-202LR.A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1988-2023·2023-06-28

    Olympus QUICKCLIP PRO hemostatic clips recalled for deployment failures

    Olympus is recalling QUICKCLIP PRO hemostatic clips due to deployment failures that could prevent proper function during GI procedures. Clip arms may fail to operate or clips may detach prematurely from tissue.

    Product
    Single Use Repositionable Clip QUICKCLIP PRO 165CM 5/BX- Intended for hemostatic metal clip for the GI Tract Catalog Number: HX-202LR.B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1989-2023·2023-06-28

    Single use hemostatic clips recalled for clip deployment and mechanical failures

    Olympus Corporation recalls QuickClip Pro hemostatic clips (13,707 units) nationwide due to device deployment failures. Complaints include clip arms failing to open or close and premature tissue detachment during clinical procedures.

    Product
    Single Use Repositionable Clip QUICKCLIP PRO 230 CM 10/BX- Intended for hemostatic metal clip for the GI Tract Catalog Number: HX-202UR.A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1613-2023·2023-05-31

    Olympus Single Use Distal Cover for Endoscope Recalled Due to Detachment Risk

    Olympus is recalling about 309,278 single-use endoscope covers that may detach during use, risking aspiration, inhalation, obstruction, or burns.

    Product
    Olympus Single Use Distal Cover Model Number MAJ-2315 used with EVIS EXERA III Duodenovideoscope TJF-Q190V; Item code: Catalogue #N5786100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1616-2023·2023-05-31

    Olympus Fine Needle Aspiration Needles Recalled for Angle Non-Conformance

    Olympus is recalling 1,297 boxes of fine needle aspiration needles due to a manufacturing defect where the needle angle does not meet specifications, resulting in slight resistance during needle advancement and retraction.

    Product
    To be used with ultrasound endoscopes for ultrasound guided fine needle aspiration (FNA) of submucosal and extramural lesions of the tracheobronchial tree and the gastrointestinal tract Models: NA-U401SX-4022, NA-U401SX-4022-A
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1615-2023·2023-05-31

    ViziShot 2 Aspiration Needle recalled for manufacturing angle defect

    ViziShot 2 Aspiration Needles are being recalled because the needle angle does not meet specifications and remains unbent, causing resistance during use. No illnesses or injuries have been reported.

    Product
    ViziShot 2 Single Use Aspiration Needle, 21G- To be used with ultrasound endoscopes for ultrasound guided fine needle aspiration (FNA) of submucosal and extramural lesions of the tracheobronchial tree and the gastrointestinal tract. Model: NA-U401SX-4021, NA-U401SX-4021-A
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1418-2023·2023-04-26

    Olympus Single-Use Endoscopic Clip Fixing Device Recalled for Deployment Failure

    Olympus is recalling single-use rotatable clip fixing devices used in endoscopy procedures. The clips may fail to deploy from the tube sheath during use.

    Product
    Single Use Rotatable Clip Fixing Device Model HX 201LR 135 - Rotatable, 165cm long, 2.8 scope channel, standard clip Model HX 201UR 135 - Rotatable, 230 cm long, 2.8 scope channel, standard clip Model HX 201UR 135L - Rotatable, 230 cm long, 2.8 mm scope channel, Long clip
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1132-2023·2023-02-22

    Olympus colonovideoscope recalled for potential microbial contamination from veterinary use

    An Olympus EVIS EXERA III colonovideoscope was used in veterinary endoscopy before being designated as a medical facility loaner, creating potential for microbial contamination.

    Product
    EVIS EXERA III Colonovideoscope-For endoscopy and endoscopic surgery within the lower digestive tract (including the anus, rectum, sigmoid colon, colon, and ileocecal valve) Model/Serial: CF-Q180AL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1103-2023·2023-02-15

    Thoracic Navigation System Recalled for Incorrect Cable Causing Grainy Imaging

    Olympus is recalling the SPiN Thoracic Navigation System (model SYS-4000) due to an incorrect DVI cable that produces grainy images during bronchoscopy procedures, requiring extended troubleshooting time.

    Product
    SPiN Thoracic Navigation System Model: SYS-4000 (SYS-4000D)
    Category
    Medical Device
    Distribution
    11 states