The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

7576–7600 of 13666

  • HighFDA (Devices)·Z-0681-2024·2024-01-17

    Abbott Alinity c Chemistry Analyzer Contains Unlabeled Latex Subcomponent

    Abbott Laboratories is recalling 1,127 Alinity c Processing Module chemistry analyzers because unlabeled latex subcomponents are present. Users with latex allergies may experience serious allergic reactions upon contact.

    Product
    Alinity c Processing Module REF 03R67-01 The Alinity c Processing Module is a fully automated chemistry analyzer allowing random and continuous access, as well as priority and automated retest processing using photometric and potentiometric detection technology. The Alinit
    Category
    Medical Device
    Distribution
    47 states
  • HighFDA (Devices)·Z-0704-2024·2024-01-17

    BIOFIRE Respiratory Panel 2.1 recalled for false negative manufacturing defect

    BioFire Diagnostics recalls 57 kits of the BIOFIRE Respiratory Panel 2.1 due to a manufacturing defect that may produce false negative results, potentially causing treatment delays or missing infections.

    Product
    The BIOFIRE Respiratory Panel 2.1 (RP2.1) is a PCR-based multiplexed nucleic acid test intended for use with the BIOFIRE FILMARRAY 2.0 or BIOFIRE FILMARRAY Torch Systems.
    Category
    Medical Device
    Distribution
    16 states
  • HighFDA (Devices)·Z-0669-2024·2024-01-17

    Vascu-Guard Peripheral Vascular Patch marketing materials contain inaccurate information

    Baxter Healthcare is recalling marketing materials for its Vascu-Guard Peripheral Vascular Patch because a cardiovascular surgery brochure contains inaccurate content conflicting with official Instructions for Use and Prescribing Information.

    Product
    Vascu-Guard Peripheral Vascular Patch (GLOBAL), Product Codes: a) VG0108N: 0.8X8 CM GLOBAL, b) VG0110N: 1X10 CM GLOBAL, c) VG0106N: 1X6 CM GLOBAL, d) VG0209N: 2X9 CM GLOBAL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0694-2024·2024-01-17

    SoClean 3 CPAP Cleaner Recalled Over Ozone Exposure Risk

    SoClean, Inc is voluntarily recalling 40,075 units of the SoClean 3 sleep equipment cleaner due to potential ozone gas exposure. The manufacturer is providing an updated user manual with safety instructions and a protective hose and mask adapter.

    Product
    SoClean 3, REF SC1400, Automated Supplemental Sleep Equipment Maintenance System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0671-2024·2024-01-17

    SPRYSTEP VECTOR Ankle-Foot Orthosis Recalled for Structural Failure Risk

    Townsend Design is recalling the SPRYSTEP VECTOR custom ankle-foot orthosis due to potential air pockets between material layers that could cause complete structural failure. Users should stop using the device and contact the manufacturer.

    Product
    SPRYSTEP VECTOR, Custom made device dynamic ankle-foot orthosis (AFO) , Reference numbers: 17V1030, 17V2030, 17V1031, 17V2031, 17V1032, 17V2032, 17V1033, 17V2033, 17V1035, 17V2035, 17V1036, 17V2036, 17V1037, 17V2037
    Category
    Medical Device
    Distribution
    47 states
  • HighFDA (Devices)·Z-0647-2024·2024-01-17

    Abiomed Oscor Introducer Kit Recalled Due to Sterile Barrier Compromise

    Abiomed is recalling its Oscor Introducer Kit due to holes in the outer pouch that may compromise the sterile barrier. Non-sterile introducers could expose patients to infection, bacteremia, or sepsis.

    Product
    Oscor Introducer Kit, 14Fr x Short Individual (0052-0001)- Introducer(s) are intended for introduction of the Impella Catheter into the body. Part Number: 0052-3014
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0702-2024·2024-01-17

    H. Pylori Diagnostic Test Recalled Due to Incorrect Expiration Date Label

    Immunostics is recalling H. Pylori diagnostic test kits due to mislabeled expiration dates. Using the product after expiration may produce false positive, false negative, or invalid results.

    Product
    Detector H. Pylori, Catalog Number IHP-30
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0703-2024·2024-01-17

    Diagnostic Test Kits for GI Panel May Return False Negatives Due to Manufacturing Issue

    BioFire FILMARRAY GI Panel diagnostic test kits may return false negative results due to a manufacturing event, potentially leading to missed diagnoses and inappropriate treatment. The affected kits were distributed to locations in 16 U.S. states.

    Product
    BIOFIRE FILMARRAY Gastrointestinal (GI) Panel is a qualitative multiplexed nucleic acid-based in vitro diagnostic test intended for use with BIOFIRE FILMARRAY Systems.
    Category
    Medical Device
    Distribution
    16 states
  • HighFDA (Devices)·Z-0641-2024·2024-01-17

    Medical diagnostic reagent recall: incorrect cell staining fluorescence

    BD Biosciences is recalling CD11b APC diagnostic reagent vials that may produce dim fluorescence signals, potentially causing false negative results and misdiagnosis of blood cancers.

    Product
    CD11b APC: ASR, REF: 340936, and CE, REF: 333143
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0698-2024·2024-01-17

    Medtronic Percutaneous Surgical Pins Recalled Due to Potential Fitting Defects

    Medtronic is recalling 4,235 percutaneous surgical pins that may have a manufacturing defect preventing proper fit into or removal from the tap cap. The pins were distributed nationwide and internationally.

    Product
    Medtronic, REF 9733235, Pin, 100mm, STERILE, PERCUTANEOUS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0644-2024·2024-01-17

    Olympus ENDOEYE Videoscope Recalled for Reprocessing Instructions Deviations

    Olympus Corporation recalls 1,403 ENDOEYE Flex endoscopic videoscopes due to deviations in reprocessing instructions. Affected devices may not be reprocessed properly for safe reuse in surgical procedures.

    Product
    OLYMPUS ENDOEYE FLEX DEFLECTABLE VIDEOSCOPE (5.4 mm diameter) Model: LTF-S190-5 Used with a video system center, light source, documentation equipment, monitor, hand instruments, electrosurgical unit, and other ancillary equipment for endoscopy and endoscopic surgery within
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0652-2024·2024-01-17

    Abiomed Introducer Kit Sterile Barrier Compromise Due to Pouch Defect

    Abiomed Introducer Kits may have holes in outer pouches that compromise sterility, exposing patients to bacterial contamination and risk of infection, bacteremia, or sepsis.

    Product
    Abiomed Kit, 14Fr Introducer, 13cm&25cm, Sterile Part of Pump Set (0048-0040, 0048-0045, 1000080)-Introducer(s) are intended for introduction of the Impella Catheter into the body. Part Number: 0052-3046
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0706-2024·2024-01-17

    XScribe Cardiac Stress Testing System may distort ECG readings

    Baxter Healthcare Corporation is recalling 2,985 units of the XScribe Cardiac Stress Testing System, version 6, due to potential distortion in electrocardiogram readings when the Source Consistency Filter is enabled. No injuries have been reported.

    Product
    XScribe Cardiac Stress Testing System, version 6, with below product names and codes: a) XS6/RS6 REVIEW WKSTN KIT, XR-6AC-BXXXX; b) XS6/RS6 REVIEW WKSTN KIT, XR-6AC-DXXXX; c) XS6/RS6 REVIEW WKSTN KIT, XR-6AC-XXXXX; d) XS6 WAM TTL KIT IEC XML BRAZIL, XSCRIBE-5AX-XXBRZ; e) XS6
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0700-2024·2024-01-17

    VADER pedicle system torque wrench may not tighten implant screws correctly

    Icotec Ag is recalling VADER pedicle system torque wrenches (Catalog Number 42-702) because the torque limiting function may malfunction, potentially leaving nut screws insufficiently tightened during implant surgery. No injuries have been reported.

    Product
    VADER pedicle system, torque wrench, Catalog Number 42-702
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-0673-2024·2024-01-17

    Boston Scientific ZOOM LATITUDE Pacemaker Programmer Software Displays Incorrect Diagnostic Dates

    Boston Scientific is recalling pacemaker programmer software that displays certain diagnostic dates incorrectly, with dates showing years in the 1990s. Affected diagnostic information may impact clinical monitoring.

    Product
    Boston Scientific Model 3120 ZOOM LATITUDE Programmer/Recorder/Monitor (PRM) installed with Model 2892 Programmer Application Software used for the following pacemaker products: ALTRUA 20, ALTRUA 40, ALTRUA 60, INSIGNIA I Entra, INSIGNIA I Plus, INSIGNIA I Ultra, NEXUS I Entra, a
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0689-2024·2024-01-17

    Olympus Updates Manual Cleaning Instructions for Cysto-Nephro Videoscope

    Olympus has updated cleaning instructions for the Model CYF-VH Cysto-Nephro Videoscope. Reusable cleaning brushes are no longer recommended for manual cleaning; single-use brushes remain compatible.

    Product
    Model No. CYF-VH, CYSTO-NEPHRO VIDEOSCOPE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0679-2024·2024-01-17

    Gamma Camera Recalls Due to Potential Patient Extremity Entrapment Hazard

    Philips BrightView XCT gamma cameras may pose an extremity entrapment hazard during certain scanning operations. A gap can form between the patient support and detector, risking fractures, lacerations, and crush injuries.

    Product
    BrightView XCT, Gamma Camera, Product Code 882482
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0705-2024·2024-01-17

    Cardiac Stress Testing System may produce distorted electrocardiogram readings

    The Q-Stress Cardiac Stress Testing System version 6 may distort electrocardiogram (ECG) readings when the Source Consistency Filter is enabled. Healthcare facilities should verify ECG readings and consult product documentation.

    Product
    Q-Stress Cardiac Stress Testing System, version 6, with below product name / product codes: a) QS6 AM12Q KIT AHA XML / QS6-BXXCS: b) QS6 AM12Q KIT BCRT IEC / QS-6CC-DGCXX: c) QS6 AM12Q KIT Z200 BCRT IEC / QS-6CC-DFCXX: d) QS6 AM12Q RS SYS AHA XML / QS-6JB-AXAXA: e) QS6 AM12Q
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0655-2024·2024-01-17

    Abiomed Introducer Kits Recalled for Sterile Barrier Pouch Defect

    Abiomed is recalling 84 introducer kits that may have holes in the outer pouch, compromising the sterile barrier. This exposes patients to microbial contamination and risk of serious infections including bacteremia and sepsis.

    Product
    Abiomed Kit, 23Fr Introducer, 11cm, Sterile Part of Pump Set (1000323)-Introducer(s) are intended for introduction of the Impella Catheter into the body. Part Number: 2000342
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0648-2024·2024-01-17

    Abiomed Oscor Introducer Kit sterile barrier holes risk infection

    Abiomed Oscor Introducer Kits may have holes in the outer pouch that compromise sterility. This could allow bacteria to enter the patient's bloodstream during catheter insertion.

    Product
    Abiomed Oscor Introducer Kit, 14Fr x Long Individual (0052-0017)- Introducer(s) are intended for introduction of the Impella Catheter into the body. Part Number: 0052-3015
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0678-2024·2024-01-17

    Gamma Camera Gap Creates Extremity Entrapment Hazard During Quality Assurance

    Philips BrightView X gamma cameras may create a gap between patient support and detector during quality assurance scans, potentially trapping a patient's extremity.

    Product
    BrightView X, Gamma Camera, Product Code 882478
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0654-2024·2024-01-17

    Abiomed Introducer Kits recalled due to sterile barrier compromise

    Abiomed is recalling Introducer Kits because holes in the outer pouch may compromise the sterile barrier, risking bacterial infection. The kits are distributed nationwide and internationally.

    Product
    Abiomed KIT, 14 Fr Introducer, 13 & 25 cm, ABMD Part of Pump Set (0048-0024, 0048-0032)-Introducer(s) are intended for introduction of the Impella Catheter into the body. Part Number: 0052-3056
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0713-2024·2024-01-17

    Wheelchair Control Device Throttle Lever May Stick During Operation

    The Scoot Control R-net wheelchair attendant controller's throttle lever may stick and fail to return to neutral, potentially causing unwanted chair movement. A total of 129 units were distributed in Tennessee and Texas.

    Product
    Scoot Control R-net, Product Number P015-61. The Scoot Control is intended to support a wheelchair attendant in controlling or maneuvering a power chair
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0715-2024·2024-01-17

    MRI systems at risk of unintended magnet shutdown during power loss

    Philips Ingenia Ambition X and S MRI systems may experience uncontrolled shutdown of the sealed magnet if cryo-cooling is lost due to power outages. This could disrupt patient scans and operations.

    Product
    (1) Ingenia Ambition X (Product Number 781356); (2) Ingenia Ambition S (Product Number 781359)
    Category
    Medical Device
    Distribution
    24 states
  • HighFDA (Devices)·Z-0682-2024·2024-01-17

    ARCHITECT c4000 Processing Module recalled for unlabeled latex component

    Abbott ARCHITECT c4000 Processing Module laboratory analyzers are recalled due to unlabeled dry natural rubber (latex) subcomponents. Individuals with latex allergies may experience allergic reactions if exposed to the undisclosed component.

    Product
    ARCHITECT c4000 Processing Module REF: 02P24-01 02P24-02 02P24-40 01R24-56 01R25-56 The Abbott ARCHITECT c4000 Processing Module is designed to perform automated chemistry tests, utilizing photometry and potentiometric technology.
    Category
    Medical Device
    Distribution
    47 states