The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

7301–7325 of 40007

  • HighFDA (Devices)·Z-1779-2024·2024-05-15

    Interact Discovery RT X-ray Systems Recalled for Component Fall Risk

    GE Healthcare is recalling certain x-ray systems because adhesive material may not be properly attached to bolts, which could cause components to fall during use.

    Product
    GE Healthcare Interact Discovery RT, Interventional fluoroscopic x-ray systems
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1765-2024·2024-05-15

    Vascular Access Catheter Recall Due to Metal Shaving Risk

    Angiodynamics is recalling 65 DURAFLOW 2 vascular access devices distributed in Virginia due to potential loose metal shavings that could enter the bloodstream and require surgical removal.

    Product
    DURAFLOW 2, 28CM STRAIGHT VASC-PAK PG- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012195
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1774-2024·2024-05-15

    Vascular access device recalls due to metal shaving contamination risk

    Angiodynamics is recalling the BioFlo DuraMax 15.5F Single Valve Sheath VascPak Kit due to possible loose metal shavings. Metal shavings could enter the bloodstream and require surgical removal.

    Product
    BioFlo DuraMax 15.5F 24cm Single Valve Sheath VascPak Kit- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H965103038181
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1775-2024·2024-05-15

    Baxter Spectrum IQ Infusion Pump recalled due to improper pre-release testing

    Baxter Healthcare is recalling one Spectrum IQ Infusion Pump that underwent improper testing before release. The device was distributed nationwide including in Massachusetts.

    Product
    Baxter Spectrum IQ Infusion Pump, Product Code 3570009
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1773-2024·2024-05-15

    Vascular catheter recalled for potential metal shavings that may cause embolization

    Angiodynamics recalled a vascular access catheter used for hemodialysis because it may contain loosely affixed metal shavings. These shavings could potentially detach and move through blood vessels, possibly requiring surgical removal.

    Product
    DURAMAX STACKED TIP 32 CM STRAIGHT VASC-PAK, 1-UP PG- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103028201
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1770-2024·2024-05-15

    Vascular access device recalled for potential metal shavings embolism risk

    Angiodynamics recalls DURAMAX STACKED TIP vascular access devices that may contain loosely affixed metal shavings. Metal shavings could embolize and potentially require surgical removal.

    Product
    DURAMAX STACKED TIP 32CM STR. BASIC KIT, 5-UP PG- Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103028055
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1760-2024·2024-05-15

    Hemodialysis vascular access kit recalled for loose metal shavings

    Angiodynamics recalls 455 DURAFLOW 2 hemodialysis kits for loose metal shavings that could embolize, potentially requiring surgical removal.

    Product
    DURAFLOW 2, 24CM STRAIGHT BASIC KIT -Indicated for use in attaining Long-Term vascular access for Hemodialysis and Apheresis. Product Number: H787103012015
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1784-2024·2024-05-15

    X-ray C-arm Tabletop Recalled for Risk of Uncontrolled Motion

    NRT X-RAY A/S recalls Intelli-C X-ray tabletops due to faulty firmware and worn motor components that may cause uncontrolled C-arm motion, potentially striking patients or operators.

    Product
    Intelli-C: Right side suspended Tabletop, REF: 03400000; Left side suspended Tabletop, REF: 03400010, used with the Intelli-C X-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1785-2024·2024-05-15

    Stryker Dynamic Mesh Mislabeled with Incorrect Catalog Number

    Stryker shipped 63 units of cranial mesh labeled as catalog 56-90614 (Gold) but actually containing 56-90314 (Blue) mesh. The mislabeling may cause procedural delays.

    Product
    Stryker 1,5/1,7MM DYNAMIC MESH- STD-MEDIUM-Intended for the reconstruction, stabilization and rigid fixation of the bony areas of the cranial skeleton. Catalog Number: 56-90614
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1786-2024·2024-05-15

    Evidence MultiSTAT analyzer foam gasket malfunction may affect test accuracy

    Randox Laboratories is recalling 40 units of the Evidence MultiSTAT analyzer because a foam gasket defect may allow light to leak into the camera during testing, potentially affecting result accuracy and delaying reporting.

    Product
    Evidence MultiSTAT with software v 3.7-Analyzer intended for the qualitative determination of parent drug molecule and metabolites of drugs in human urine Catalog Number: EV4115
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1692-2024·2024-05-08

    Left ventricular assist system implant kit recalled for potential inflow cannula seal leak

    Thoratec HeartMate 3 left ventricular assist system implant kits may develop a leak at the seal interface between the inflow cannula and titanium apical cuff, potentially compromising device function.

    Product
    Thoratec HeartMate 3, LVAS Implant Kit, REF:106524US, Sterile EO, RxOnly
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1693-2024·2024-05-08

    Thoratec HeartMate 3 Left Ventricle Assist System Recalled for Seal Leak

    Thoratec recalls HeartMate 3 left ventricle assist systems due to potential leaks at the seal interface. The FDA Class I recall affects 659 implanted devices worldwide.

    Product
    Thoratec HeartMate 3, LVAS Implant Kit, REF:106524INT, Sterile EO, RxOnly
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1715-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate may fail to lock properly

    Zimmer orthopedic plates may have thread defects preventing locking screws from properly mating, potentially resulting in loss of fixation and need for additional surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 4 Holes, 80 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 7-2357-018-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1744-2024·2024-05-08

    Radiation Therapy Planning System May Report Dose Values Too High

    RayStation radiation therapy planning software versions 9.0.0.113 and 9.0.1.142 may report dose values that are higher than actual. The Class II recall affects 63 units distributed worldwide.

    Product
    RayStation 9.0.0.113 and 9.0.1.142. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1750-2024·2024-05-08

    RayStation Radiation Therapy System Recalled for Potential Dosing Error

    RayStation versions 13.0.0.1547, 13.1.0.144, and 13.1.1.89 radiation therapy treatment planning systems are recalled due to a potential software error in source-to-surface distance calculations that could affect radiation dose delivery.

    Product
    RayStation 13.0.0.1547, 13.1.0.144 & 13.1.1.89. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1718-2024·2024-05-08

    Zimmer Periarticular Locking Plate System recalled due to faulty screw threads

    Zimmer recalls Periarticular Locking Plate System devices due to thread defects that may prevent proper screw locking and cause surgical delay or loss of fixation.

    Product
    ZPLP(Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Left, 10 Holes, 158 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-018-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1712-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate Locking Screw Defect

    Zimmer's Periarticular Locking Plate may have defective locking holes that prevent screws from properly locking, risking loss of bone fixation and requiring additional surgery.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 10 Holes, 158 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1735-2024·2024-05-08

    Jackson-Pratt 3-Spring Reservoir Drain Kits Shipped Without Sterilization

    Cardinal Health is recalling specific lots of Jackson-Pratt 3-Spring Reservoir Kits because they were shipped to users before sterilization. Unsterilized surgical drains pose an infection risk.

    Product
    Jackson-Pratt 3-Spring Reservoir Kit with PVC Round Drain, 400mL, 7Fr., REF SU130-401D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1756-2024·2024-05-08

    Philips Spectral CT Oncology Imaging System Recall: Laser Reflection Hazard

    Philips recalls 12 units of its Spectral CT Oncology Essentials system because a marking laser could reflect off the gantry cover, potentially causing misdiagnosis and incorrect patient treatment.

    Product
    The Oncology Essentials Package of the Spectral CT imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1726-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plates May Have Improper Screw Locking

    A thread form defect in the locking holes of Zimmer surgical bone plates may prevent locking screws from securing properly, potentially causing loss of fixation during surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 4 Holes, 80 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1724-2024·2024-05-08

    Zimmer ZPLP Fibular Plate May Fail to Lock Properly During Surgery

    The ZPLP Distal Lateral Fibular Plate may have a thread defect preventing screws from locking properly, potentially compromising surgical fixation and requiring further intervention.

    Product
    ZPLP Distal Lateral Fibular Plate, Right, 8 Holes, 132 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-017-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1731-2024·2024-05-08

    Medtronic Invos Infant Sensor Cables recalled for manufacturing defects

    Covidien is recalling 1,122 Medtronic Invos Reusable Infant Sensor Adapter Cables due to manufacturing defects in connectors. The defects may cause error codes or non-functioning monitoring channels.

    Product
    Medtronic Invos, Reusable Infant Sensor Adapter Cable for PM7100, REF: PMAC71RIC
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-1713-2024·2024-05-08

    Zimmer Periarticular Locking Plate screw-mating defect risks surgical fixation loss

    Zimmer's Periarticular Locking Plate System has a thread defect that may prevent proper screw locking, potentially causing loss of surgical fixation. Affected units distributed worldwide.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 12 Holes, 184 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-12
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1706-2024·2024-05-08

    Zirconium oxide dental restoration blocks may develop cracks during sintering

    IVOCLAR VIVADENT recalls 12,525 zirconium oxide blocks for dental restorations after defective units may develop cracks during sintering, potentially causing restoration fractures.

    Product
    IPS e.max ZirCAD CER/in. Prime A3 C17/5 -A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth Article Number: 758439
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1738-2024·2024-05-08

    Jackson-Pratt Drainage Kits Shipped Unsterilized in Voluntary Removal

    Cardinal Health is voluntarily removing Jackson-Pratt drainage kits (Lot 210751D6) that were shipped without sterilization. The unsterilized devices pose an infection risk if used in patient care.

    Product
    Jackson-Pratt Universal Connector PVC Tubing Anti Reflux Transparent Y, REF SU130-4601
    Category
    Medical Device
    Distribution
    Distributed nationwide