The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

7051–7075 of 13666

  • HighFDA (Devices)·Z-1252-2024·2024-03-13

    FDA Recalls Apollo Onyx Delivery Microcatheter Due to Labeling Mismatch

    FDA is recalling Apollo Onyx Delivery Microcatheters distributed in the US with incorrect European labeling. The devices contain different indications for use than those approved for the US market.

    Product
    The Apollo Onyx Delivery Microcatheter (AOMC) is a DMSO-compatible, single-lumen, end hole catheter designed for the infusion of the Onyx liquid embolic system (LES). The catheter has a semi-rigid proximal shaft and a highly flexible distal shaft to facilitate the advancement of
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1255-2024·2024-03-13

    Paragon 28 Phantom TTC Nail recalled for unsterilized distribution

    Paragon 28, Inc. is recalling the Phantom TTC Nail (10.0 X 150mm, RIGHT) distributed in California, as these devices were shipped prior to sterilization. Unsterilized surgical implants pose a serious risk of infection and complications.

    Product
    Phantom TTC Nail, TTC Nail, 10.0 X 150mm, RIGHT , REF: P31-600-175L
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1272-2024·2024-03-13

    Medical imaging software measurements incorrect in specific cases

    FUJIFILM's Synapse PACS Version 7.2.200 produces incorrect measurements when analyzing certain breast imaging scans without pixel spacing data. This measurement error could affect diagnostic accuracy.

    Product
    Synapse PACS - Version 7.2.200
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1220-2024·2024-03-13

    VITROS 3600 Immunodiagnostic Systems May Cause Aspiration During Sample Processing

    The VITROS 3600 Immunodiagnostic System is being recalled due to potential aspiration of sample containers during laboratory processing, which may result in erroneous test results.

    Product
    VITROS 3600 Immunodiagnostic System (New and Refurbished)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1258-2024·2024-03-13

    Embrace Drill Tower Surgical Instruments Recalled Due to Mixed-Up Type Descriptions

    Waldemar Link recalled Embrace Drill Tower surgical instruments because type descriptions ("standard" vs "wedged") are mixed up in the product overview documentation. Surgeons may select incorrect instrument types due to the confusion.

    Product
    Embrace Drill Tower, Standard/Lateral (25mm)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1248-2024·2024-03-13

    MRI Systems Show Incorrect Spatial Field Gradient Values

    Canon Medical's MRI systems display incorrect Spatial Field Gradient values that are lower than actual, which may cause discomfort for patients with MR-conditional implanted devices during scanning.

    Product
    MRI system: Vantage Orian, Vantage Fortian, Model: MRT-1550
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1070-2024·2024-03-06

    VOCSN Pediatric breathing package spiral wrap detachment risk during ventilation

    Ventec Life Systems recalls VOCSN Patient Breathing Packages because the spiral wrap may detach during ventilation, compromising the breathing circuit and creating a risk of serious injury or death, especially for ventilator-dependent patients.

    Product
    VOCSN Patient Breathing Package (Pediatric, Active, Oxygen, Blue) REF PRT-01013-000 with pouch REF PRT-00802-001). Used with the VOCSN Unified Respiratory System which provides continuous or intermittent ventilatory support for the care of individuals who require mechanical ven
    Category
    Medical Device
    Distribution
    8 states
  • CriticalFDA (Devices)·Z-1123-2024·2024-03-06

    Medline Surgical Kits Recalled for Potential Sterility Failure

    Medline Industries is recalling 533 units of gynecological laparoscopy kits and trays manufactured with Nurse Assist irrigation and saline components due to potential lack of sterility. The affected products were distributed nationwide in the U.S. and internationally.

    Product
    Medline Kits, trays, and packs labeled as follows: a) GYN LAPAROSCOPY, REF CDS984900M; b) GYN LAPAROSCOPY CDS, REF CDS983913S; c) GYN LAPAROSCOPY CDS, REF CDS983913T; d) GYN LAPAROSCOPY CDS, REF CDS983913U; e) GYN LAPAROSCOPY CDS, REF CDS983913V
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1136-2024·2024-03-06

    Centurion LVAD Maintenance Kits Recalled for Potential Sterility Failure

    Medline Industries is recalling Centurion LVAD maintenance kits and driveline management trays due to sterility concerns in irrigation solution components from Nurse Assist. The solutions may be non-sterile and could pose infection risks.

    Product
    Centurion Kits, trays, and packs labeled as follows: a) A C DAILY WET KIT, REF DM405A; b) BWH DAILY DRIVELINE MGMT KIT, REF DM640; c) DAILY DRIVELINE MGMT SYSTEM, REF DM600; d) DAILY MAINTENANCE SYSTEM LVAD, REF DM870A; e) DAILY MAINTENANCE SYSTEM LVAD, REF DM870A; f
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1102-2024·2024-03-06

    Surgical kits and trays recalled due to lack of sterility

    Medline Industries is recalling over 3,200 surgical kits and trays containing components that may lack sterility. The recalled products could pose infection risk to patients if used during surgical procedures.

    Product
    MEDLINE Kits, trays, and packs labeled as follows: a) ASC GENERAL MINOR CDS, REF CDS983673G; b) ASC GENERAL MINOR CDS, REF CDS983673I; c) C NURSE BAG KIT, REF DYKM1425; d) DAILY DRIVELINE MGMT KIT w/PER, REF DT18700; e) GASTRIC CULTURE PACK, REF DYNJ53966A; f) GASTRI
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1120-2024·2024-03-06

    Medline wound care trays recalled due to sterility defect

    Medline Industries is recalling Wound Care Trays due to potential lack of sterility in solution components. The recall affects 72,624 units distributed nationwide and internationally.

    Product
    Medline Kits, trays, and packs labeled as follows: WOUND CARE TRAY - LATEX-FREE, REF DYND06002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1091-2024·2024-03-06

    Medline Tracheostomy Care Kits Recalled for Non-Sterile Component Solutions

    Medline Industries is recalling care and cleaning kits for tracheostomy and stomas due to component solutions that may not be sterile. The affected kits contain Nurse Assist-manufactured saline and irrigation solutions distributed in the U.S., Puerto Rico, Canada, UAE, and Panama.

    Product
    MEDLINE TRAY care and cleaning kits and trays for Tracheostomy and Stomas, labeled as: a) STOMA & TRACH CLEANING KIT, REF DYNDJ1129; b) TRACH CARE TRAY, REF DYNDJ1057A; c) TRACHEOSTOMY CARE KIT, REF DYNDA1893A; d) TRACH CARE TRAY, REF DYNDA1482
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1113-2024·2024-03-06

    Medline Medical Kits Recalled Due to Potential Lack of Sterility

    Medline is recalling approximately 3,900 medical device kits and trays nationwide due to potential sterility failures in irrigating solution components. The affected products may not be sterile, creating a risk of infection.

    Product
    Medline Kits, trays, and packs labeled as follows: a) PORT ACCESS TRAY, REF DYNDA2863; b) PORT ACCESS TRAY, REF DYNDA2863H; c) ULTRASOUND GUIDED IV START KIT, REF DYNDV2518; d) ULTRASOUND GUIDED IV START KIT, REF DYNDV2518H; e) KIT ULTRASOUND PIV START, REF DYNDV2445;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1061-2024·2024-03-06

    AirLife Adult Manual Resuscitator Recalled for Ventilation Failure Risk

    Vyaire Medical recalls 3.6 million AirLife Adult Manual Resuscitators due to defective oxygen tubing components that may fail to deliver proper ventilation, risking hypoxia. Affected units were manufactured in 2017 or earlier.

    Product
    AirLife Adult Manual Resuscitator, 40" (1.0m) Oxygen Reservoir Tubing, Adult Mask, REF 2K8005
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1122-2024·2024-03-06

    Medline kits and trays recalled for potential lack of sterility

    Medline Industries is recalling surgical kits and trays containing irrigation solutions that may not be sterile due to manufacturing issues. The non-sterile solutions could increase infection risk during surgical and obstetrical procedures.

    Product
    Medline Kits, trays, and packs labeled as follows: a) L&B CDS-LF, REF CDS980273D; b) LABOR AND DELIVERY, REF DYNJ907794; c) LACERATION TRAY, REF DYNDL1864A; d) OBSTETRICAL, REF DYNJ908877; e) UMC EP VAGINAL DELIVERY, REF DYNJ83093;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1164-2024·2024-03-06

    Medtronic Duet External Drainage System catheter disconnection risk recalled

    Medtronic recalls Duet External Drainage and Monitoring System catheter units (REF 46915) due to potential disconnection from stopcock connectors. Worldwide distribution includes 14,139 units.

    Product
    Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Ventricular Catheter, REF 46915, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1166-2024·2024-03-06

    Medtronic Duet Catheter System Recalled for Potential Disconnection Risk

    Medtronic Duet External Drainage System catheters may disconnect from stopcocks, potentially compromising cerebrospinal fluid management. The FDA Class I recall affects 3,889 units distributed worldwide.

    Product
    Medtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Lumbar Catheter, REF 46917, Sterile EO, Rx Only. Used to drain cerebrospinal fluid (CSF) as a means to reduce intracranial pressure and CSF volume.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1063-2024·2024-03-06

    AirLife Adult Manual Resuscitator recalled for ventilation failure risk

    Vyaire Medical is recalling 4,572 units of AirLife Adult Manual Resuscitators due to defective components that may cause improper ventilation or complete ventilation failure, potentially resulting in hypoventilation, hypoxia, or death.

    Product
    AirLife Adult Manual Resuscitator, 40" (1.0 m) Oxygen Reservoir Tubing, Adult Mask, CO2 Detector, REF 2K8005C2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1095-2024·2024-03-06

    Medline Medical Kits and Trays Recalled for Potential Sterility Failure

    Medline Industries is recalling certain medical kits and trays that may contain non-sterile solutions. Healthcare facilities should discontinue use of affected batches to prevent patient exposure to potential contamination.

    Product
    MEDLINE Kits, trays, and packs labeled as follows: a) CATH LAB CDS, REF CDS840228F; b) PEDIATRIC PORT A CATH TRAY, REF DYNDC2128B; c) PK, RADIOLOGY, REF DYNJ44087A; d) PORT ACCESS PACK-LF, REF DYNJ0352159C; DYNJ0352159D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1103-2024·2024-03-06

    Medline surgical kits and trays recalled for sterility defects

    Medline Industries recalls 5,969 surgical kits and trays that may lack sterility due to components from Nurse Assist. The non-sterile irrigation solutions could compromise product safety.

    Product
    MEDLINE Kits, trays, and packs labeled as follows: a) C-SECTION, REF DYNJ904653G; b) DRESSING TRAY, REF M101426; c) ENDO KIT, REF DYKE1387; d) ENDO KIT, REF DYKE1364B; e) ENDO KIT, REF DYKE1892; f) ENDO KIT W/ BLUE TOTE BAG, REF DYKE1648I; g) EYE KIT, REF DYKM2222;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1131-2024·2024-03-06

    Medline Centurion Eye Prep Kit Sterilization Defect Recall

    Medline Industries is recalling Centurion Eye Prep Kits due to potential lack of sterility in irrigation solution components manufactured by Nurse Assist.

    Product
    Centurion Kits, trays, and packs labeled as follows: EYE PREP KIT, REF ET1010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1060-2024·2024-03-06

    AirLife Adult Manual Resuscitator Kits Recalled for Component Failure

    Vyaire Medical is recalling 3,636 AirLife Adult Manual Resuscitator kits. Manufacturing defects can cause component failure that prevents proper ventilation, potentially resulting in fatal hypoxia.

    Product
    AirLife Adult Manual Resuscitator, Oxygen Reservoir Bag, Adult Mask, CO2 Detector, REF 2K8004C2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1132-2024·2024-03-06

    Medline Centurion surgical trays and kits recalled for potential non-sterile solutions

    Medline Industries is recalling 14,234 units of Centurion surgical kits and trays that may contain non-sterile irrigation solutions. The affected products were manufactured using compromised Nurse Assist components.

    Product
    Centurion Kits, trays, and packs labeled as follows: a) BASIC PROCEDURE TRAY, REF MNS13600; b) BWH DAILY DRIVELINE MGMT KIT, REF DM640A; c) CIRCUMCISION TRAY, REF CIT6180; d) INCISION & DRAINAGE TRAY, REF ID1690; e) LACERATION TRAY, REF SUT19510; f) LACERATION TRAY,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1126-2024·2024-03-06

    Medline Surgical Kits Recalled for Potential Sterility Failure

    Medline Industries recalls surgical kits and trays manufactured with non-sterile solutions due to contaminated Nurse Assist components. Kits distributed nationwide and internationally may lack proper sterility, posing infection risk.

    Product
    Medline Kits, trays, and packs labeled as follows: a) CATARACT PACK, REF VAL011CTASD; b) CATARACT PACK, REF DYNJ68875F; c) CATARACT PACK, REF DYNJ54869F; d) CATARACT PREP PACK, REF DYNJ44917L; e) E-BLEPH CDS, REF CDS983585G; f) EYE CDS, REF CDS983916G; g) EYE KIT,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1135-2024·2024-03-06

    Medline recalls Centurion Laceration Trays for potential sterility defect

    Medline Industries recalls 576 units of Centurion Laceration Trays nationwide because Nurse Assist-supplied components may lack sterility, posing potential health risks in medical procedures.

    Product
    Centurion Kits, trays, and packs labeled as follows: LACERATION TRAY, REF ST11670A
    Category
    Medical Device
    Distribution
    Distributed nationwide