Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

5101–5125 of 40520

  • HighFDA (Devices)·Z-1127-2025·2025-02-19

    Cardinal Health Presource Kits recalled for endotoxin contamination risk

    Cardinal Health is recalling Presource Kits containing surgical strips and patties due to potential endotoxin contamination. Approximately 973,785 units were distributed in the US, Canada, and Saudi Arabia.

    Product
    Cardinal Health Presource Kits: 1) KIT,NEURO LAMI,MD ANDERSON, Catalog Number:PN76LMM14; 2) KIT,NEURO LAMI,MD ANDERSON, Catalog Number:PN76LMMD9; 3) KIT,NEURO LAMI,MD ANDERSON, Catalog Number:PN76LMMDX;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1119-2025·2025-02-19

    Pyxis Medication and Anesthesia Dispensing Systems Recalled for Software Vulnerabilities

    CareFusion recalls Pyxis medication dispensing systems due to software issues that could delay access to medications, result in incorrect doses, or allow unauthorized access.

    Product
    (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1164-2025·2025-02-19

    Diagnostic HPV Verification Panel Recalled Due to Quality Control Failures

    Microbiologics Inc is recalling HPV verification test panels (REF 8235) due to quality control failures that allowed defective units to be released. The panels may produce invalid test results or fail to detect HPV.

    Product
    Microbiologics Multi-Strain Human Papillomavirus (HPV) Verification Panel (Inactivated Pellet), REF 8235; in-vitro diagnostic test
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1128-2025·2025-02-19

    Cardinal Health Urology Robotic Packs recalled for potential endotoxin contamination

    Cardinal Health Presource Kits for robotic urology surgery are being recalled due to potential endotoxin contamination in surgical strips and patties. No adverse events have been reported.

    Product
    Cardinal Health Presource Kits: 1) UROLOGY ROBOTIC PACK, Catalog Number:SOT4FRUWFA; 2) UROLOGY ROBOTIC PACK, Catalog Number:SOT4FRUWFB; 3) UROLOGY ROBOTIC PACK, Catalog Number:SOT4FRUWFC
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1169-2025·2025-02-19

    Vios Bedside Monitor Pulse Oximeter Sensor Premature Failure and Incorrect Warnings

    Murata Vios, Inc. is recalling the Vios Monitoring System Bedside Monitor, Model BSM2050, due to premature failure of the pulse oximeter SpO2 sensor. When the sensor fails, the system displays an incorrect warning that may mask the actual monitoring problem.

    Product
    Vios Monitoring System Bedside Monitor, Model BSM2050, Software Version Numbers 1.54.20 and 1.56.00
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1122-2025·2025-02-19

    BD Pyxis MedStation ES Medication Cabinet Drawer and Door Failures Recalled

    The FDA is recalling BD Pyxis MedStation ES medication cabinets due to potential drawer and door failures that could delay medication access. Affected healthcare facilities should check their devices and contact the manufacturer if malfunctions occur.

    Product
    BD Pyxis MedStation ES (Med ES Main) REF: 323. Intended to securely store and dispense medications to a qualified and authorized healthcare provider.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1163-2025·2025-02-19

    HPV Diagnostic Control Panel Recall Due to Quality Control Failures

    Microbiologics is recalling a lot of HPV diagnostic control materials due to inadequate quality control during release. The control's HPV 16 L1 concentration is too low, potentially causing test failures and invalid results in clinical laboratories.

    Product
    Microbiologics Multi-Strain Human Papillomavirus (HPV) Control Panel (Inactivated Pellet), REF 8234; in-vitro diagnostic test
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1121-2025·2025-02-19

    LVIS Intraluminal Support Device May Fail to Deploy Properly

    MicoVention Terumo LVIS stent devices may fail to advance from the introducer due to PTFE material on the stent loop. Eleven units (Lot 0000456768) distributed in China are affected.

    Product
    MicoVention Terumo, LVIS Intraluminal Support Device, REF: 213522-CAS, od, 3.5 mm, TL 22 mm, WL 18 mm, Sterile R, CE0297. The intended purpose of the LVIS Device is to serve as a stent-assisted coiling (SAC) device providing support to the embolic coils used in the treatment of…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1132-2025·2025-02-19

    Cardinal Health Presource Surgical Kits Recalled for Potential Endotoxin Contamination

    Cardinal Health is recalling approximately 973,785 Presource Kits due to potential endotoxin contamination in non-sterile surgical strips and patties. The kits were distributed to healthcare facilities worldwide.

    Product
    Cardinal Health Presource Kits: 1) KIT,NASAL SEPTOPLASTY,FAIRVIEW, Catalog Number:PE29NSFG4; 2) KIT,NASAL SEPTOPLASTY,FAIRVIEW, Catalog Number:PE29NSFG5 3) KIT,NASAL SEPTOPLASTY,FAIRVIEW, Catalog Number:PE29NSFG6 4) KIT,NASAL SEPTOPLASTY,FAIRVIEW, Catalog Number:PE29NSFG7 5)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1125-2025·2025-02-19

    BD Pyxis MedStation 4000 Recalled for Drawer and Door Failures

    CareFusion 303, Inc. is recalling the BD Pyxis MedStation 4000 medication cabinet due to potential drawer and door failures that could delay access to stored medications.

    Product
    BD Pyxis MedStation 4000 REF: 303. Intended to securely store and dispense medications to a qualified and authorized healthcare provider.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1120-2025·2025-02-19

    BD Pyxis Medication Dispensing Systems Recalled for Insufficient Labeling

    CareFusion is recalling six models of BD Pyxis medication management systems due to insufficient labeling regarding potential delays in medication access. The manufacturer is strengthening product labeling to address this risk.

    Product
    (1) BD Pyxis MedStation ES, Catalog No. 323; (2) BD Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) BD Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis MedStation 4000 Console, Catalog No. 309; (5) BD Pyxis MedStation 4000, Catalog No. 303; (6) BD Pyxis…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1123-2025·2025-02-19

    BD Pyxis MedStation Auxiliary ES medication cabinet drawer and door failures

    BD Pyxis MedStation Auxiliary ES medication cabinets are being recalled due to potential drawer and door failures following increased complaints. The failures could delay access to medications stored in the cabinet.

    Product
    BD Pyxis MedStation Auxiliary ES REF: 324. Intended to securely store and dispense medications to a qualified and authorized healthcare provider.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1019-2025·2025-02-12

    Ivenix Infusion System software recalled for pump malfunction risk

    The FDA recalled Ivenix Infusion System software versions 5.9.2 and earlier for potential device malfunctions that could affect medication delivery. Two known anomalies may cause pump failure or improper infusion rates.

    Product
    Ivenix Infusion System (IIS), LVP Software LVP-SW-0005. Indicated for use in a hospital and in outpatient care environments for the controlled administration of fluids through clinically accepted routes of administration.
    Category
    Medical Device
    Distribution
    15 states
  • SevereFDA (Devices)·Z-1047-2025·2025-02-12

    Newborn Resuscitator Kit Recalled for Inline Spring Defect

    414 newborn resuscitator kits (ROi CPS LLC) recalled for a potential spring defect in the Inline Controller that could prevent proper ventilation pressure in labor and delivery settings.

    Product
    regard Item Number: 830106006, LD01114F - Newborn Kit containing the component Neo-Tee Resuscitator. Convenience kit to be used in Labor and Delivery.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1075-2025·2025-02-12

    Levofloxacin Antimicrobial Susceptibility Discs Recalled Due to Packaging Mislabeling

    Oxoid Limited is recalling 1,406 units of Lev5 Levofloxacin susceptibility discs because packaging may contain Norfloxacin discs instead, which could affect laboratory test results.

    Product
    Lev5, REF CT1587B, 50 Susceptibility discs Levofloxacin 5 ug, IVD, CE 2797
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-1085-2025·2025-02-12

    Finger entrapment hazard in Philips Allura fluoroscopy patient tables

    Philips is recalling AD7 and AD7X patient tables from Allura and Azurion fluoroscopy systems. During manual repositioning, fingers can become trapped between the guiding rails and tabletop, potentially causing injury.

    Product
    Allura Xper FD20/20 System Code: (1) 722038
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1077-2025·2025-02-12

    Philips AD7 and AD7X patient tables recalled due to finger entrapment risk

    Philips has recalled the AD7 and AD7X patient tables used in medical imaging systems because fingers can become entrapped between the tabletop and guiding rails during manual repositioning, potentially causing injury.

    Product
    Allura Xper FD10 Catalog (1) 722003 (2) 722010 (3)722026
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1093-2025·2025-02-12

    Philips Azurion patient tables recalled for finger entrapment risk

    Philips is recalling Azurion 7 M12 and Allura patient tables used in medical imaging systems due to a finger entrapment hazard during manual repositioning. Operators and service personnel may suffer finger injury if fingers are caught between the tabletop and guiding rails.

    Product
    Azurion 7 M12 System Code: (1) 722078 (2) 722223 (3) 722233
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1073-2025·2025-02-12

    VNS Therapy Generator May Stop Delivering Stimulation Due to Mechanical Defect

    LivaNova's SenTiva VNS generators (48 units) may stop delivering stimulation due to a mechanical defect. Patients may experience return to baseline seizure or depressive symptoms and may require replacement surgery.

    Product
    SenTiva, REF: 1000C, Generators Part of the VNS Therapy System with Microburst Stimulation. Used for Vagus Nerve Stimulation (VNS).
    Category
    Medical Device
    Distribution
    41 states
  • HighFDA (Devices)·Z-1110-2025·2025-02-12

    IntelliVue Patient Monitor MX550 May Fail to Alarm on Ventilator Disconnection

    Philips IntelliVue Patient Monitor MX550 units may fail to generate an alarm when a Hamilton ventilator is disconnected, creating a patient safety risk. The monitor could remain silent without alerting clinical staff.

    Product
    IntelliVue Patient Monitor MX550. Model Number: 866066
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1084-2025·2025-02-12

    Philips Allura and Azurion Patient Tables Recall Due to Finger Entrapment Risk

    Philips is recalling AD7 and AD7X patient tables used in Allura and Azurion medical imaging systems due to a finger entrapment hazard during manual repositioning. Operators and service personnel are at risk of finger injury.

    Product
    AlluraXperFD20/10 System Code: (1) 722029
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1099-2025·2025-02-12

    Belmont Medical 3-Spike Disposable Set May Leak During Use

    The Belmont Medical 3-Spike Disposable Set may leak during priming due to a crack in its female quick connector, potentially delaying warmed infusions in hospital settings.

    Product
    Belmont Medical 3-Spike Disposable Set used with the Belmont Rapid Infuser RI-2. Designed to be used in general operation in hospital or alternate care environments to provide warmed blood and fluids to any patients e10 kg requiring warmed infusion. Part Number:903-00006
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1086-2025·2025-02-12

    Philips AD7 and AD7X Patient Table Finger Entrapment Risk

    The Philips AD7 and AD7X patient tables pose a finger entrapment risk during manual repositioning. Operators and service personnel could sustain finger injuries from the gap between the longitudinal guiding rails and tabletop.

    Product
    AlluraXperFD20/15 System Code: (1) 722058
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1043-2025·2025-02-12

    X-Ray imaging systems may allow radiation exposure beyond safety limits

    GE Medical Systems is recalling Definium 656HD and Discovery XR656HD X-Ray systems due to an Automatic Exposure Control defect that may allow radiation exposure to exceed intended safety limits.

    Product
    Definium 656HD & Discovery XR656HD (GTINs: 00840682138598, 00195278840226, 00840682136709). X-Ray imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide